Installation
51
EN
Connection with hose connector
Carefully screw the hose connector 3 to the
appliance’s gas connector 1 (½” thread
ISO 228-1), placing the seal 2 between
them. The hose connector reduction 4 can
also be screwed to the hose connector 3,
depending on the diameter of the gas hose
used. After tightening the hose connector(s),
push the gas hose 6 onto the hose
connector and secure it with the clamp 5,
which must be compliant with applicable
regulations.
The gasket is necessary to avoid gas leaks.
At the end of the installation, check for any
leaks with a soapy solution, never with a
flame.
Connection with a steel hose
Make the connection to the gas mains
using a continuous wall steel hose whose
specifications comply with the applicable
standard.
Carefully screw the connector 3 to the gas
connector 1 of the appliance, placing the
seal 2 between them.
Connection using a rubber hose
complying with current standards is
only permitted if the hose can be
inspected along its entire length.
The inside diameter of the hose
must be 8 mm for LPG and 13 mm
for Natural gas and Town gas.