WIRING A REMOTE FAN
When using a remote fan with a chimney style hood, follow the instructions noted below.
NOTE: The chimney style hood is designed to accept a 3-speed fan motor only. It is not designed to accept a
variable speed fan.
1. The Molex plug mounted within the front portion of the hood supplies power to the remote fan.
2. Connect the “male” Molex pigtail (included) with the remote fan to the Molex plug.
3. Route the wire ends into the hood’s “J-Box”.
4. Connect these wires to the remote fan wires within the hood’s “J-Box”. (See Figure 13)
5. If using a remote fan for a 30” wide chimney hood, remove and discard the adapter plate. (See Figure 12)
A high heat sensor is integrated within the complete line of Prizer Hoods. It is activated when the exhaust
temperature reaches 200° F (93° C) and de-activates as the temperature decreases to 186° F (85° C). If the fan is
operating on the low speed, and the high heat sensor engages, the fan motor will automatically change to high
speed until the temperature decreases.
HIGH HEAT SENSOR