15. TECHNICAL DATA
Voltage: 120 V~ 60 Hz max. 10 A
Power: 1250 W
Pressure: 1,5 MPa (15 bar)
Water tank capacity: 2 L
Size LxHxD: 260x470x365 mm
Cord length: 1750 mm
Weight: 10,9 kg
Beans container capacity: 400 g
16. DISPLAYED MESSAGES
DISPLAYED MESSAGE POSSIBLE CAUSE SOLUTION
FILL TANK Insucient water in the tank (A16). Fill the tank with water and/or insert it cor-
rectly, pushing it as far as it will go until it
clicks into place.
EMPTY GROUNDS CONTAINER The grounds container (A10) is full.
Empty the grounds container and drip tray
(A12), clean and replace. Important: when
removing the drip tray, the grounds container
MUST be emptied, even if it contains few groun-
ds. If this is not done, when you make the next
coees, the grounds container may ll up more
than expected and clog the machine.
GROUND TOO FINE ADJUST
MILL
The grinding is too ne and the coee is delive-
red too slowly or not at all.
Repeat coee delivery and turn the grin-
ding adjustment dial (A5) (g. 13) one click
clockwise towards "7" while the coee mill is
in operation. If after making at least 2 coees
delivery is still too slow, repeat the correction
procedure, turning the Grinding adjustment
dial another click until delivery is correct (see
section: “8.4 Adjusting the coee mill”). If the
problem persists, make sure the water tank
(A16) is fully inserted.
If the water softener lter (C4) is present, an
air bubble may have been released inside the
circuit, obstructing delivery.
Insert the hot water spout (C6) in the appliance
and deliver a little water until the ow beco-
mes regular.
INSERT GROUNDS CONTAINER
After cleaning, the grounds container has not
been replaced (A10).
Remove the drip tray (A12) and insert the
grounds container.
ADD PREGROUND COFFEE With the “pre-ground coee” function selected,
pre-ground coee has not been poured into the
funnel (A4).
Place pre-ground coee in the funnel (g. 17)
or deselect the "pre-ground" function.
DESCALE The machine must be descaled. The descaling procedure described in section
“12. DESCALING” needs to be performed as soon
as possible.
Loading ...