8 | CK 15-20 E / CKT 15-20 E WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
SPECIFICATION
WARNING Fire
Combustible materials such as furniture, papers, clothes
and curtains must be kept at least 3 feet (0.9 m) from the
heater.
Never place any fl ammable, combustible or insulating
objects or materials, such as laundry, blankets, magazines,
containers with fl oor polish or gasoline, spray cans or
similar on the appliance or in direct proximity to it.
15.3 Specifi cation table
CK 15 E CK 20 E CKT 15 E CKT 20 E
Part number 074058 074057 230345 230346
Power supply single phase single phase single phase single phase
Voltage 120 V 240 V 208 V 120 V 240 V 208 V
Wattage 1500 W 2000 W 1500 W 1500 W 2000 W 1500 W
Amperage 12.5 A 8.3 A 7.5 A 12.5 A 8.3 A 7.5 A
Required circuit breaker size 15 A 15 A 15 A 15 A 15 A 15 A
Required wire size 14 AWG 14 AWG 14 AWG 14 AWG 14 AWG 14 AWG
Temperature range 41°F - 86°F / 5°C - 30°C
Frost protection setting 44.6°F / 7°C
Operating noise 49.7 dB(A)
Height 18.1˝ / 46 cm
Width 13.2˝ / 33.5 cm
Depth 4.8˝ / 12.3 cm
Weight 8.0 lb / 4.4 kg