6 | CK 15-20 E / CKT 15-20 E WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
SAFETY
INSTALLATION
10. Safety
Only licensed electricians should carry out the maintenance and
repair of this appliance.
10.1 General safety information
We guarantee trouble-free operation and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
10.2 Instructions, standards and regulations
Note
Observe all applicable national and local regulations and
instructions.
11. Appliance description
This appliance is a wall mounted electric heater. It is particularly
suitable for heating rooms, such as work rooms, kitchens, bath-
rooms, wash rooms etc.
11.1 Standard delivery
- Wall mount bracket
- Bottom bracket
12. Installation
DANGER Electrocution
- If installing the appliance in rooms with a bath and/
or shower, take the relevant safety zone into ac-
count in accordance with the information on the ap-
pliance type plate.
- Install the appliance in such a way that switching
and control equipment cannot be touched by a per-
son in the bath or shower.
DANGER Fire
- Only fi t the appliance to a vertical wall that is heat-
resistant to at least194°F(90 °C).
- Maintain minimum clearances to adjacent surfaces.
- Never install the appliance directly below a wall
socket.
Check the hole distances for the wall mounting bracket in the
dimensioned drawing.
Secure the wall mounting bracket with suitable fasteners.
The horizontal and vertical slots in the wall mounting bracket
enable alignment if drilled holes are not completely accurate.
Hook in the appliance so that both top protrusions are in-
serted into the slots in the wall mounting bracket.
Secure the appliance with the bottom bracket and one screw
against unintentional unhooking. To do so, hook the bottom
bracket from the back into the rear panel.
13. Electrical connection
DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
!
Damage to the appliance and the environment
- Observe the type plate. The specifi ed voltage must
match the mains voltage.
Never install the appliance directly below an outlet.
In case of ROMEX wire, install ½" ROMEX connector in knockout.
In case of Greenfi eld, please use ½" Greenfi eld connector.
13.1 Terminal block
We recommend using stranded wire to connect to the terminal
block. Crimp a ferrule over stranded bare wire to ensure a good
connection.
Consult the chart below for the recommended torque amounts on
the terminal block screws.
Screw Diameter (mm) Torque (N•cm) Torque (lbf•in)
2.8 30-40 2.65-3.54
2.8-3 35-50 3.09-4.42
3-3.2 50-60 4.42-5.31
3.2-3.6 60-80 5.31-7.08
3.6-4.1 90-120 7.96-10.62
4.1-4.7 120-180 10.62-15.93
4.7-5.3 150-200 13.27-17.7
Using the proper torque specifi cations to secure wire to the wiring
block helps to avoid personal loss or property damage.
See 15.3, “Specifi cation table”, pg. 8 for information on the
proper wire gauge size.
14. Appliance handover
Explain the functions of the appliance to the user. Draw special
attention to the safety information. Hand the operating and instal-
lation instructions to the user.