Loading ...
Loading ...
Loading ...
10
www.napoleongrills.com
CAUTION!
Make sure cylinder valve is in its full o posion. (Turn clockwise to stop).
Check cylinder valve features to ensure it has proper external mang threads. (Cylinder Valve Marked:
USE WITH TYPE 1)
Inspect hose shipped with the unit for damage. Never aempt to use damaged or plugged equipment.
See your local LP Gas Dealer for repairs.
When connecng regulator assembly to the cylinder valve, hand ghten black QCC1 nut clockwise to a
posive stop. DO NOT use a wrench to ghten. Use of a wrench may damage the quick closing coupling
nut and result in a hazardous condion.
Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject
to accidental damage.
Open cylinder valve fully (counter-clockwise). Turn the on/o valve at the unit slowly to the on posion
and use a soapy water soluon to check all connecons for leaks as indicated in the diagrams before
aempng to light the appliance. If a leak is found, turn tank valve o and do not use the appliance unl
repairs can be made.
Enclosures For LP (Propane) Gas Supply Systems
If you build an enclosure for an LP gas cylinder, follow these recommended specicaons. You must also follow
local codes.
An enclosure for an LP-gas cylinder shall be venlated by openings at both the upper and lower levels of
the enclosure.
This shall be accomplished by one of the following:
One side of the enclosure shall be completely open;
OR
For an enclosure having four sides, a top, and a boom:
a) At least two venlaon openings shall be provided in the sidewalls of the enclosure, located within 5 in (127
mm)
of the top of the enclosure, equally sized, spaced at 180 degrees, and unobstructed. The opening(s) shall have
a total free area of not less than 1 in
2
per lb (14.2 cm
2
/ kg) of stored fuel capacity.
b) Venlaon opening(s) shall be provided at oor level of the enclosure and shall have a total free area of not
less than 1/2 in
2
per lb (7.1 cm
2
/ kg) of stored fuel capacity. If venlaon openings at oor level are in a side
wall, there shall be at least two openings. The boom of the openings shall be 1 in (25.4 mm) or less from the
oor level and the upper edge no more than 5 in (127 mm) above the oor level. The openings shall be equally
sized, spaced at 180 degrees, and unobstructed.
c) Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 inch (3.2mm) diameter
rod.
Venlaon openings in sidewalls shall not communicate directly with other enclosures of the appliance.
Cylinder valves shall be readily accessible for hand operaon. A door on the enclosure to gain access to the
cylinder valve is acceptable, provided it is non-locking and can be opened without the use of tools. Designs
using a cover to gain access to the cylinder and cylinder valve shall be provided with handles or equivalent at a
minimum of 180 degrees apart to facilitate liing of the cover.
There shall be a minimum clearance of 2 inches (50.8mm) between the lower surface of the oor of the LP gas
supply cylinder enclosure and the ground.
The design of the enclosure shall be such that (1) the LP gas supply cylinder(s) can be connected, disconnected
and the connecons inspected and tested outside the cylinder enclosure; and (2) those connecons which
could be disturbed when installing the cylinder(s) in the enclosure can be leak tested inside the enclosure.
Loading ...
Loading ...
Loading ...