A power connection kit must be
used to supply power to the
Zoneline unit. The appropriate kit
is determined by the voltage, the
means of electrical connection and
the amperage of the branch circuit.
Connections of 208 or 230 volt
circuits may be with a line cord kit
or a permanent connection kit.
Connections of 265 volt circuits
must be with a permanent connec-
tion kit. NEC requires permanent
connection for installations over
250 volts.
All wiring, including installation of
the receptacle, must be in accor-
dance with the National Electrical
Code and local codes, ordinances
and regulations.
Power Connection
Tandem,
15 Amp.
Perpendicular
20 Amp.
Large Tandem
30 Amp.
11
Electrical wiring wall outlets
230/208 volt.
Parts Required
Exterior grille/louver** Wall case** Zoneline unit Room cabinet*
Power
connection
kit***
*Shipped with the Zoneline unit
**Check essential elements list on unit
***Line cord connection shown only as an example
Phillips screwdriver
Flat-blade screwdriver
Tools Needed