User manual Vacuum Cleaner
IMPORTANT SAFETY INSTRUCTIONS!
When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER.
WARNING: To reduce the risk of fire, electric shock, or injury:
SAVE THESE INSTRUCTIONS
Household Use Only
To assist you in identifying your vacuum’s components, the parts have been numbered as follows.
1. Align slot in handle tube with tab in connector. Insert the handle tube into connector. Tighten collar at base of handle tube onto the connector until it locks, “snaps”.
2. Snap cord assembly into the cord clip located on the left side of the collar. Leave excess cord at the power head to allow movement.
Make sure the Disposable Odor Fighting HEPA Inner bag is in place. DO NOT operate the cleaner without a HEPA Inner bag. Plug the power cord into an electrical outlet and press the On Low ( l ) - On High ( ll ) - OFF ( O ) switch on handle assembly when ready to operate.
3. Up-Position Lock - Place foot on power head and lean handle back gently to release lock for vacuum use. Return handle to the full upright position to engage lock. The handle should be rotated to center before returning to upright position. Note: Do not operate the unit while in the upright and locked position. Do not let the unit run while in any one stationary position for any period of time. Keep the unit moving while in operation.
4. Carry Handle - Raise the carry handle located on back of the unit for easy lifting, carrying, and stair vacuuming. Lower the handle during use to eliminate obstruction.
5. Easy Power Cord Storage - Raise carrying handle and wrap power cord around carry handle and vacuum handle.
6. To release cord, twist cord dump located on vacuum handle 1/2 turn. Slide cord off handle.
Both the vacuum handle and carry handle can be used for convenient, space saving storage of cleaner.
Hang cleaner by carry handle on a sturdy fastener or vacuum handle on a closet rod.
This new ORECK Upright is one of the finest, fastest, and strongest units in its class. You’ll love the way it cleans, gets under things, and it’s SO lightweight and easy to use.
The following are a few simple suggestions regarding its operation:
The performance of your new cleaner greatly depends upon care and maintenance. The instructions in this manual will guide you in performing basic care and maintenance. To obtain the most satisfying years of service read the instructions and keep them handy for future reference.
Your Oreck includes an Odor Fighting HEPA Inner Bag. The disposable inner bag plays a very important role in the efficiency of your ORECK vacuum. The purpose of the disposable inner bag is to trap dirt, but at the same time it must be porous enough to allow air to pass through. If the disposable inner bag becomes clogged, no air can pass through the vacuum and cleaning cannot take place, regardless of the vacuum’s power.
To keep your Upright vacuum operating at maximum efficiency, change the disposable inner bag frequently.
DO NOT FILL ABOVE THE LINE INDICATED ON THE DISPOSABLE INNER BAG.
Be sure the disposable inner bag is installed properly. Note: All disposable inner bags are not the same. Oreck offers HEPA and non-HEPA inner bags. Your Oreck HEPA or non-HEPA inner bags have been designed to be used with the ORECK Upright vacuum. Using bags other than genuine Oreck HEPA or non-HEPA disposable inner bags will affect the cleaning ability of your vacuum and could cause damage to it.
Your new Oreck Upright features the 360º Glide turning system. The 360º Glide offers an entirely new level of maneuverability to your lightweight Oreck Upright. No installation necessary. Simply turn the handle of your Oreck Upright to maneuver the unit. Go left, Go right, make sharp turns under and around furniture.
The belt on your vacuum cleaner controls the speed of the revolving brush and is very important for the effective operation of the cleaner. If the belt becomes stretched or cut, it will cause the revolving brush to stop completely or slow down. See instructions in the manual for replacing belt.
The vacuum cleaner motor bearings are factory lubricated and sealed. Further lubrication is not required.
CAUTION
Wood Floors, Soft (Vinyl, Asphalt Tile, etc.) Floor Surfaces and Polished Floor Finishes
Use floor and floor finish manufacturer’s recommended methods of cleaning. The roller brush may also scuff very soft finishes. Do not operate the unit while in the upright and locked position. Do not let the unit run while in any one stationary position for any period of time. Keep the unit moving while in operation.
Note: At least once a month, check for and remove excessive lint, string or hair from revolving brush. Patented cleaning grooves on brush roll will allow easier cleaning. Wipe the outside of the cleaner with a damp cloth. Also clean the connector deflector assembly area, base of cleaner and fan housing area. If there is dust in the outer bag, vacuum it or shake it out.
A little preventative maintenance will keep your cleaner looking new and will ensure continued cleaning effectiveness.
WARNING: Unplug cord from electrical outlet before servicing.
BAG REMOVAL:
7. Unzip outer bag completely.
8. Pull bag cardboard collar to release bag dock door from connector. Bag dock door will hinge downward.
9. Gently pull bag cardboard collar upward out of the bag dock. Saniseal® dust seal will close automatically.
BAG INSTALLATION:
10. Slide the cardboard collar completely onto bag dock door.
11. Firmly push bag dock door with both thumbs on indication point until it snaps.
WARNING: Unplug cord from electrical outlet before servicing.
12. Remove the door by removing the hold down screw located on side of power head.
13. Fold door away from the power head and lift it away.
14. Remove the belt from the motor drive shaft and brush roll pulley.
15. Loop the new belt over the brush roll pulley. Place the opposite end of the belt on the motor drive shaft.
16. Replace the door by placing the bottom tab on door into slots located inside power head and pressing the door closed.
17. Replace the hold down screw and tighten.
WARNING: Unplug cord from electrical outlet before servicing.
Your Oreck Vacuum has a brushroll that can be replaced after heavy use for improved performance.
18. Remove the baseplate by removing 5 screws. Then, remove the belt and brushroll from the housing.
19. Snap the new brushroll into place.
20. Reassemble the belt.
21. Reassemble the baseplate.
WARNING: Unplug cord from electrical outlet before servicing.
22. Turn the power head over. With baseplate facing up, remove the screw located in the center of each edge brush. Remove both edge brushes and replace with new ones. Replace both screws and tighten.
The light assembly should be replaced by an Oreck authorized service center whenever it fails to light during operation.
IMPORTANT: On plush and new carpets, stuffing may occur inside the intake tube and the lower tube assembly. This is due to excessive fuzz and loose cuttings in the carpet. Stuffing could occur for the first few cleanings until all the loose material is removed. Due to the high efficiency of the cleaner, many older carpets will cause stuffing when the cleaner is first used on them. If your vacuum cleaner does not pick up properly, or makes unusual noise and the outer bag does not fluff up or balloon open, follow these steps:
WARNING: Unplug cord from electrical outlet before servicing.
23. Check for blockage at the mouth of the intake opening. If there is blockage, remove it with long-nose pliers, a screwdriver or coat hanger. If you can not reach the blockage, remove baseplate. Remove the base plate by removing 5 screws see “Replacing Brushroll”).
24. If the blockage is not at the base, remove lower tube. Unhook bag spring, releasing bottom of bag.
25. Twist lower collar counterclockwise to slide up. Pull tube out of base. Check for blockage. If blockage is in the tube, remove with a coat hanger.
26. If tube is not blocked, look into fan housing. Remove debris with long-nose pliers, a screwdriver or coat hanger.
27. To reassemble, check O-ring on tube, and replace if damaged. Replace tube by first lining up slot at base of tube with tab inside fan housing.
28. Insert tube and push down until the tube is seated. Make sure O-ring is in place against fan housing opening. Replace and tighten collar until collar locking tabs are locked in place. Reattach bag spring.
29. Many times blockage occurs due to a full HEPA Inner bag causing dirt to back down the air flow system. When that happens, the blockage will be at the top of the system, starting in the area where the HEPA Inner bag connects to the connector assembly.
Note: If the above actions do not correct the problem, contact an Oreck authorized service center or call the customer service center. US: 1-800-989-3535 Canada: 1-888-676-7325
Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing this guide.
All other servicing should be done by an Oreck authorized service center.
Problem | Check | What to do |
| Cleaner will not run | • Not plugged in properly. • No electricity in wall outlet. | • Be sure cleaneris firmly plugged into wall outlet. • Check electricalsource – fuse or circuit breaker. |
| Cleaner does not pick up. | • Filter Bag is full. • Nozzle or intake pivot clogged. • Belt is broken or stretched. • Brush is worn. • Bag tube clogged. • Bag pores are clogged with fine dust. • Impeller fan is broken. | • Replace filter bag. See “Replacing Disposable Odor Fighting HEPA Inner Bag”. • Clear obstruction. • Replace belt. • See “Replacing Brushroll”. • Clear obstruction. • Change bag. • Return to Service Center for repair. |
| Unit still does not operate properly. | • Check all the above points. | • Contact Oreck for service. |
All replacement parts are sold separately. To order, call our customer service group or visit our website. Please have your model number from the data label on the bottom of the unit.
Replacement Parts
| Item | |
| Belts, 3 Pack | 0300604 |
| Odor Fighting HEPA Inner Bag, 8 Pack | CCPK8OH |
Customer Service Hotline
USA: 1-800-989-3535 Canada: 1-888-676-7325
Reference file: Oreck U7211ECPQ Axis Upright Vacuum Cleaner
Series: https://oreckfactoryoutlets.com/vacuums/axis-upright/