33
Special feature
Intelligent Recovery: See configuration menu item 6- Intelligent Recovery operation.
Compressor protection: See configuration menu item 10- Select compressor lockout delay
Heat Pump Temperature Lockout: See configuration menu item 21-Heat pump compressor lockout temperature
PROGRAMMING
Set Current Time clock and Day of the week
Press MENU for displaying main menu button.
Press SET TIME button to enter to the clock-setting
mode.
Press the day to set current day of the week. Press
or
to adjust the minutes or hours. Press NEXT STEP
to shift between setting minutes and setting hours.
Press DONE to save & exit (or press CANCEL to exit
without changing the time).
Set current day
of the week
Set current minutes
or hours
Press NEXT STEP to
shift from setting minuts
to setting hours
Press DONE to
confirm and exit
Press CANCEL to
cancel current setting
and exit