Loading ...
1
This manual apply for SAS6000UTK-7,used with Single Stage,Multi-Stage,Heat pump
SPECIFICATION
Power Supply ……………………… Dual Power 24VAC (18-30VAC,50/60Hz) or Battery Powered
Terminal Load…………………………1.0 A per terminal, 2.0A maximum total load
Set point Temperature Range………….41 to 95(5 to 35)
Operating Ambient…………………….32 to 122 (0 to 50)
Operating Humidity…………………...90% non-condensing max
Shipping Temperature Range…………. 14 to +140 (-10 to 60)
Dimensions……………………………. 5.9 inch×4.5 inch×1.2inch(150m115mm ×32mm)
Color……………………………………White
FEATURE
Apply with various kind of heating and cooling system. Including Single stage, Multi-stage
And Heat Pump (Up to 3-stage heat, 2-stage cool, with Aux. Or Emergency heat)
Large LCD display with backlight, continuous backlight option