Loading ...
Loading ...
V-ZUG Ltd
V-ZUG Ltd, Industriestrasse 66, CH-6301 Zug
[email protected], www.vzug.com
Planning aid
International collection
Kitchen appliances
J001059-R20
24.05.17
62
11
Range hoods
Technical information on the range hoods can be found in the document J32836 «TechInfo for range hoods».
11.1
General notes
If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances), safe operation
is only possible providing a room negative pressure of 4Pa (0.04mbar) is not exceeded at the location of the appliance.
Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or windows
and in combination with an air-intake/exhaust-air wall box or by other technical means.
Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing any
damage.
Minimum distance to the hob
If a V-ZUG appliance is being combined with a third-party brand (hob or range hood) and the stipulated minimum distance
between the combined appliances is different, then the greater of the two must be observed. The minimum distance is
measured between the bottom edge of the range hood and the bottom of the pot or pan.
If the appliance is installed over gas hobs, each cooking zone must be fitted with an ignition fuse.
Extraction mode
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or other
fuels.
Observe the local fire regulations.
Installation notes
In addition to the correct dimensioning of the exhaust duct, it is also necessary to ensure a sufficient inflow of fresh air.
to replace the air that is being extracted.
Avoid routing the exhaust duct to the side through the chimney casing.
Planning features for non-destructive de-installation and maintenance of the appliance:
Do not route telescopic casing in suspended ceilings.
Avoid silicone joints between the telescopic casing and the appliance.
All plastering, plasterboarding, wall papering or painting work is to be carried out prior to installing the appliance.
11.2
Special hoods
Special hood type DSTS9 (64004) may not be used in combination with gas hobs.
Special hood type DSMS (64005) may only be operated in combination with a gas hob of V-ZUG gas hob type:
GAS321GKBZ, GAS321EKBZ, GAS421GSAZ, GAS421GSBZ, GAS641GKAZ, GAS641EKAZ, GAS641GSAZ,
GAS641GSBZ, observing the permitted combination installation variants. The content of the operating and installation in-
structions for the listed gas hob must be observed! If operating a permitted gas appliance, the hob hood must be fitted with
the dedicated gas deflector 1031218 (accessory)! Operating a gas appliance without the gas deflector is not permitted!