Wolf VS24 24" Panel Ready Vacuum Sealing Drawer

User Manual - Page 4

For VS24.

PDF File Manual, 20 pages, Read Online | Download pdf file

VS24 photo
Loading ...
Loading ...
Loading ...
4
|
Wolf Customer Care 800.222.7820
Installation Requirements
The vacuum seal drawer can be installed in a standard or
ush inset application. Finish the edges of the opening.
They may be visible when the drawer is open.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below.
For ush inset installations, a minimum
1
/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
An anti-tip block must be installed to prevent the vacuum
seal drawer from tipping forward when opened.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Vacuum Seal Drawer 75 lb (34 kg)
TRIM OVERLAP
Top 0" (0)
Bottom 0" (0)
Sides
11
/16" (18)
SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 10 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 3'
(.9 m)
Rating plate location
RATING
PLATE
Loading ...
Loading ...
Loading ...