User Manual

This is the main product document for model 7500.

The file format is pdf, 40 pages, you can download this manual here .

background
7500
Universal Programmable
Wireless Thermostat Kit
For Systems Up to 3 Heat / 2 Cool
Store this manual for future reference
©2018 Braeburn Systems LLC • All Rights Reserved • Made in China.
7500-110-02
®
User Manual
®
Read all instructions before proceeding
See Wireless Setup Guide for Wireless Setup Instructions
background
Contents
1 About Your Wireless Thermostat Kit
Thermostat Features ................................................ 3
Thermostat and Display ........................................... 4
Control Module .........................................................8
2 Setting User Options
Advanced User Options ............................................ 9
Table of User Options ............................................. 10
Service Monitors (Filter, UV and Humidifier Pad) .........11
Extended Hold Time Period ......................................11
Temporary Override Adjustment Limit ..................... 12
Program Override Time Limit .................................. 12
Thermostat Lock Code ........................................... 12
3 Setting Your Program Schedule
Setting the Time and Day ....................................... 13
Tips Before Setting Your Program Schedule ........... 14
Programming a 7 Day Residential Schedule ........... 17
Programming a 5-2 Day Residential Schedule ........ 19
Programming a 7 Day Commercial Schedule ......... 20
4 Operating Your Thermostat
Setting the System Control Mode ......................... 22
Setting the Fan Control Mode ............................... 23
Setting the Temperature ....................................... 24
Status Indicators .................................................. 25
Communication Loss ............................................26
Remote Sensor - Low Batteries ............................27
Program Event Indicator ....................................... 28
Resetting the Thermostat ..................................... 28
5 Additional Operation Features
Auto Changeover Mode ....................................... 29
Adaptive Recovery Mode ..................................... 30
Programmable Fan Mode ..................................... 31
Compressor Protection ........................................ 31
Locking and Unlocking the Thermostat................. 32
AC Power Monitor ............................................... 34
Indoor Remote Sensing ....................................... 34
Outdoor Remote Sensing .................................... 35
Humidification and Dehumidification ................... 36
6 Thermostat Maintenance
Thermostat Cleaning ............................................ 38
Battery Replacement ........................................... 38
User Manual 2
background
Congratulations! You are in control of one of the easiest-to-use wireless thermostats on the market today.
This thermostat has been designed to provide you with years of reliable performance and comfort control.
Features
Reliable BlueLink
®
wireless technology
• SpeedBar
®
multi-function button simplifies programming and setting changes.
• SpeedSet
®
programming gives you the option of programming all 7 days at once.
Convenient HOLD feature lets you override the program schedule.
Large 5 sq. in. bright blue backlit display is easy to read.
Extra large display characters make viewing settings even easier.
User selectable service monitors remind you of required system maintenance.
Precise temperature accuracy keeps you in control of your comfort.
Convenient programmable fan mode.
Optional indoor or outdoor remote sensing (wired or wireless).
3 User Manual
background
1
About Your Thermostat
User Manual 4
BACK NEXT
HUMID
1
2
3 4
8
9
11
12
13
5
6
14
15
16
10
7
background
5 User Manual
* BACK and NEXT are secondary functions of the PROG and HOLD buttons. When in programming or
configuration modes, BACK and NEXT appear in the display screen indicating that the PROG and HOLD buttons
now function as BACK and NEXT.
** Also see #24 on page 7.
Room Temperature ...................... Displays the current room temperature
Set Temperature .......................... Displays the current set point temperature
Outdoor Temperature Indicator ... Displays along with the outdoor temperature reading**
BACK Indicator* ........................... BACK button is active
NEXT Indicator*............................ NEXT button is active
Humidity Indicator ..................... Indicates when there is a call for humidification or dehumidification
Service Indicators ...................... Displays various service/maintenance information
Fan Indicator ................................ Indicates when the system fan is running
Wireless Indicator ........................ Indicates a wireless connection
(flashes when connection has been lost)
Low Battery Indicator .................. Indicates when the batteries need to be replaced
Hold Mode Indicator ................... Indicates if the thermostat is in HOLD mode
Lock Mode Indicator ................... Indicates if the thermostat is locked
System Status Indicator ............. Displays information about the status of the system
Day of the Week ........................... Displays the current day of the week
Program Event Indicator.............. Displays the program event
Time of Day ................................. Displays the current time of day
1
2
3
4
5
6
7
8
9
10
11
Thermostat Display
12
13
14
15
16
background
INSTRUCTIONS
DAY/TIME
BACK NEXT
15
16
23
17 18 19 20
21
22
24
25
User Manual 6
1
About Your Thermostat
background
7 User Manual
Reset Button ............................... Resets current time, program and user settings
SYSTEM Button ............................ Selects the system you want to control
DAY/TIME Button .......................... Sets the current time and day of the week
PROG Button................................. Selects programming mode or press for 3 seconds to select SpeedSet
®
BACK Button* ............................... Secondary function of the PROG button - moves back a setting
HOLD Button ................................. Enters/Exits the HOLD mode (program bypass)
NEXT Button* ............................... Secondary function of the HOLD button - moves to next setting
RETURN Button ............................ Returns to normal mode from program or setting modes
FAN Button ................................... Selects the system fan mode
Quick Reference Instructions ...... Stored in slot located at top of thermostat
SpeedBar
®
................................... Increases or decreases settings (time, temperature, etc.)
Outdoor Temperature ................... If a Braeburn
®
outdoor sensor was connected you can view the outdoor
temperature by pressing the PROG and HOLD buttons at the same time.
Humidity Setpoint ........................ If a Braeburn wireless humidity sensor is connected you can view the
current humidity or make adjustments to the humidity setpoint by
pressing the DAY/TIME and RETURN buttons at the same time.
Battery Compartment .................. Located in the back of thermostat
Thermostat
15
16
17
18
19
20
21
22
23
24
* BACK and NEXT are secondary functions of the PROG and HOLD buttons. When in programming or
configuration modes, BACK and NEXT appear in the display, indicating that the PROG and HOLD buttons
now function as BACK and NEXT.
25
background
Control Module
Your thermostat communicates wirelessly with a control
module installed on or near your heating/cooling equipment.
This control module is wired directly to your equipment.
NOTE: There is a return air sensor connected to the control
module to maintain default temperature control should
the batteries ever become drained in the thermostat. If the
return air plenum sensor becomes disconnected, the
thermostat will display the words PLEN SENS LOSS. If you
see this message, contact a local service technician.
User Manual 8
background
INSTRUCTIONS
DAY/TIME
2
Setting User Options
Advanced User Options
User options allow you to customize some of your
thermostat’s features.
Most users will not need to
make any changes to the settings in this section.
To access the User Options menu, press and hold
the RETURN button for 3 seconds until the screen
changes and displays the first User Option.
Press the SpeedBar
®
or to change the
setting
for the displayed User Option. After you
have changed your
desired setting, press NEXT
(HOLD) to advance to the next User Option. You
may also press BACK (PROG) to move backwards
through the User Options.
When your changes are complete, press RETURN to exit.
INSTRUCTIONS
DAY/TIME
BACK NEXT
9 User Manual
background
Table of User Options
No. User Options Factory Setting Comments Pg.
Default Options
1 Filter Service OFF OFF Disables filter service monitor feature.
Monitor 30, 60, 90, Selects a number of days that must pass before the
120, 180, 365
thermostat will flash a Service Filter reminder
in the display screen.
2 UV Light Service OFF OFF Disables UV service monitor feature.
Monitor 180, 365 Selects a number of days before the thermostat will
flash a Service UV reminder in the display screen.
3 Humidifier Pad OFF OFF Disables pad service monitor feature.
Service Monitor 180, 365 Selects a number of days before the thermostat will
flash a Service Humid reminder in the display screen.
4 Extended Hold Period LONG LONG Selects long (permanent) hold mode.
24HR Selects 24 hour (temporary) hold mode.
5 Temporary Override 0 ADJ 0, 1, 2,
or
3
Selects a temporary temperature adjustment limit of
Adjustment Limit ADJ 0 0 (disabled), 1˚, 2˚ or 3˚.
6 Program Override 4 TEMP 4, 3, 2 or 1 Selects a temporary program override time limit of
Time Limit TEMP 1, 2, 3 or 4 hours.
7 Thermostat Lock Code 000 0-9 Select a 3 digit lock code of 0-9 for each digit.
NOTE: Some user options may not be available, depending on how your thermostat was configured in the
Installer Settings (see Installer Manual). A detailed description of each User Option follows this table.
11
11
11
11
12
12
12
User Manual 10
background
11 User Manual
Service Monitors
(Filter, UV and Humidifier Pad)
User Options 1, 2 and 3
There are three user selectable service monitors that will display
reminders for a required air filter, UV bulb or humidifier pad
replacement. The SERVICE segment flashes in the display
along with FILTER, UV or HUMID. When the service interval
has been reached, and required cleaning or replacement has
been performed, press the RETURN button to reset the
timer. Select OFF or a set number of days before the reminder
will appear.
Extended Hold Period
User Option 4
The Extended Hold Period lets you select the period your thermostat will hold the temperature when the HOLD
mode is activated (See Setting the Temperature, page 23). When LONG is selected the thermostat will hold your
temperature indefinitely. When 24HR is selected, the thermostat will hold your temperature for 24 hours and
then return to the current program at that time. Not available in non-programmable mode.
Service
Reminders
background
Temporary Override Adjustment Limit
User Option 5
The Temporary Override Adjustment Limit will limit how
much the temperature can be adjusted from the current set point
when the thermostat is used in the programmable mode. This
setting will not allow the user to override the temperature past
the selected limit amount of 1, 2 or 3 degrees
from the current
set point. When the user reaches the adjustment
limit the screen
will flash ADJ. A setting of 0 disables the adjustment limit.
The Temporary Override Adjustment Limit can also be used in
the non-programmable mode if the keypad lockout security
level is set to level 1 (See Installer Guide).
Program Override Time Limit
User Option 6
The Program Override Time Limit allows you to set a maximum time limit (in hours) that the thermostat will
return to the program after a temporary temperature adjustment has been made (See Setting the Temperature,
page 24).
You may select 1, 2, 3 or 4 hours. Not available in non-programmable mode.
Thermostat Lock Code
User Option 7
The Thermostat Lock Code sets a 3-digit code that you may use at any time to lock or unlock the thermostat.
Setting the code in the user options mode does not activate the lock feature (See Locking/Unlocking Thermostat,
page 32). You may choose a 3-digit code with each digit being 0-9.
User Manual 12
background
13 User Manual
DAY/TIME
BACK NEXT
Setting the Time and Day
1. In normal operating mode, press the DAY/TIME
button. The display will switch to the day/time
setting mode and the hour will be flashing.
2. Press the SpeedBar
®
up or down to adjust the
hour, press NEXT.
3. Press the SpeedBar up or down to adjust the
minute, press NEXT.
4.
Press the SpeedBar up or down to adjust the day
of the week.
5. Press RETURN to exit.
3
Setting Your Program Schedule
BACK and NEXT are
secondary functions of the
PROG and HOLD buttons.
background
Tips Before Setting Your Program Schedule
Make sure your current time and day of the week are set correctly.
When programming, make sure the AM and PM indicators are correct.
Various installer settings such as auto changeover mode and temperature adjustment limits may affect your
programming flexibility.
Your NIGHT event cannot exceed 11:50 p.m.
BACK and NEXT are secondary functions of the PROG and HOLD buttons (see page 7).
This thermostat has been configured with one of the following programming options:
Residential 7 day programming mode with 4 events per day (default)
Residential 5-2 (weekday/weekend) programming mode with 4 events per day
Commercial 7 day programming mode with 2 events per day
Non-Programmable mode
NOTE: If this thermostat was configured In the Installer Settings to be
non-programmable, then you cannot set a user program. If you press
the PROG or HOLD buttons, the word “NONE” will appear in the display,
indicating there is no program present. See the Installer Guide for
different configuration options.
User Manual 14
background
Energy Saving Programs
This thermostat comes pre-programmed with a default energy saving program. The following tables outline
the pre-programmed times and temperatures for heating and cooling in each of your 4 daily events (2 events if
configured for commercial mode). If you wish to use these settings then no further programming is necessary:
MORN
DAY
EVE
NIGHT
Time: 6:00 pm
Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
Time: 8:00 am
Heat: 62˚ F (17˚ C)
Cool: 85˚ F (29˚ C)
Time: 6:00 am
Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
Time: 10:00 pm
Heat: 62˚ F (17˚ C)
Cool: 82˚ F (28˚ C)
4 Event
All Days
Residential 7 Day Programming
Factory Settings
Time: 8:00 am
Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
OCCUPIED
UNOCCUPIED
Time: 6:00 pm
Heat: 62˚ F (17˚ C)
Cool: 85˚ F (29˚ C)
2 Event
All Days
Commercial 2 Event Programming
Factory Settings
15 User Manual
background
Weekday Weekend
MORN
DAY
EVE
NIGHT
Time: 6:00 pm
Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
Time: 8:00 am
Heat: 62˚ F (17˚ C)
Cool: 85˚ F (29˚ C)
Time: 6:00 am
Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
Time: 10:00 pm
Heat: 62˚ F (17˚ C)
Cool: 82˚ F (28˚ C)
4 Event
Time: 6:00 pm
Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
Time: 8:00 am
Heat: 62˚ F (17˚ C)
Cool: 85˚ F (29˚ C)
Time: 6:00 am
Heat: 70˚ F (21˚ C)
Cool: 78˚ F (26˚ C)
Time: 10:00 pm
Heat: 62˚ F (17˚ C)
Cool: 82˚ F (28˚ C)
Residential 5-2 Day Programming– Weekday/Weekend
Factory Settings
User Manual 16
background
17 User Manual
DAY/TIME
BACK NEXT
Programming a 7 Day Residential Schedule
The 7 day residential programming mode gives you the option to program individual days (1 day at a time) or to
use SpeedSet and program the entire week (all 7 days) with a 4 event program schedule.
Setting All 7 Days at Once (SpeedSet
®
)
NOTE: Setting all 7 days at once will copy over any previously programmed individual days.
1. Hold the PROG button
for 3 seconds. The display will
switch to SpeedSet programming mode. All 7 days
of the week will appear and the hour will be flashing.
2. Press SYSTEM to select HEAT or COOL.
3. Press the SpeedBar
®
up or down to adjust the hour
for the MORN (morning) event. Press NEXT.
4. Press the SpeedBar up or down to adjust the minute
for the MORN event. Press NEXT.
5.
Press the SpeedBar up or down to adjust the
temperature
for the MORN event. Press NEXT.
6. Press the SpeedBar up or down to adjust the fan
setting for the MORN event. Press NEXT.
7. Repeat steps 3-6 for the DAY, EVE and NIGHT events.
8. If needed, repeat steps 2-7 to program the opposite mode (HEAT or COOL).
9. Press RETURN to exit.
BACK and NEXT are
secondary functions of the
PROG and HOLD buttons.
background
DAY/TIME
BACK NEXT
Setting Individual Days (7 Day Residential)
1. Press the PROG button. The display will switch to
programming mode. M (Monday) will be displayed
and the hour will be flashing.
2. Press SYSTEM to select HEAT or COOL.
3. Press DAY/TIME to select the day you would like
to program.
4. Press the SpeedBar
®
up or down to adjust the hour
for the MORN (morning) event. Press NEXT.
5. Press the SpeedBar up or down to adjust the minute
for the MORN event. Press NEXT.
6. Press the SpeedBar up or down to adjust the
temperature for the MORN event. Press NEXT.
7. Press the SpeedBar up or down to adjust the fan setting
for the MORN event. Press NEXT.
8. Repeat steps 4-7 for your DAY, EVE and NIGHT events.
9.
If needed, repeat steps 3-7 to select a different day to program.
10. If needed, repeat steps 2-9 to program the opposite mode (HEAT or COOL).
11. Press RETURN to exit.
BACK and NEXT are
secondary functions of the
PROG and HOLD buttons.
User Manual 18
background
DAY/TIME
BACK NEXT
Programming a 5-2 Day Residential Schedule
The 5-2 day residential programming mode allows you to program Monday - Friday with one 4 event schedule
and then allows you to change Saturday and Sunday with a different 4 event schedule.
1. Press the PROG button. The display will switch to
programming mode. The days M, TU, W, TH, and F
will be displayed and the hour will be flashing.
2. Press SYSTEM to select HEAT or COOL.
3. Press the SpeedBar
®
up or down to adjust the hour
for the MORN (morning) event. Press NEXT.
4. Press the SpeedBar up or down to adjust the minute
for the MORN event. Press NEXT.
5. Press the SpeedBar up or down to adjust the
temperature for the MORN event. Press NEXT.
6. Press the SpeedBar up or down to adjust the fan
setting for the MORN event. Press NEXT.
7. Repeat steps 3-6 for your DAY, EVE and NIGHT events.
8. Repeat steps 3-7 for your weekend (S, SU) program.
9. If needed, repeat steps 2-9 to program the opposite mode (HEAT or COOL).
10. Press RETURN to exit.
BACK and NEXT are
secondary functions of the
PROG and HOLD buttons.
19 User Manual
background
DAY/TIME
BACK NEXT
Programming a 7 Day Commercial Schedule
The 7 day commercial programming mode gives you the option to program individual days (1 day at a time) or to
use SpeedSet and program the entire week (all 7 days) with a 2 event program schedule.
Setting All 7 Days at Once (SpeedSet
®
)
NOTE: Setting all 7 days at once will copy over any previously programmed individual days.
1. Hold the PROG button
for 3 seconds. The display will
switch to SpeedSet programming mode. All 7 days of
the week will appear and the hour will be flashing.
2. Press SYSTEM to select HEAT or COOL.
3. Press the SpeedBar
®
up or down to adjust the hour
for the OCCUPIED event. Press NEXT.
4. Press the SpeedBar up or down to adjust the minute
for the OCCUPIED event. Press NEXT.
5. Press the SpeedBar up or down to adjust the
temperature for the OCCUPIED event. Press NEXT.
6. Press the SpeedBar up or down to adjust the fan
setting for the OCCUPIED event. Press NEXT.
7. Repeat steps 3-6 for your UNOCCUPIED event.
8. If needed, repeat steps 2-7 to program the opposite mode (HEAT or COOL).
9. Press RETURN to exit.
BACK and NEXT are
secondary functions of the
PROG and HOLD buttons.
User Manual 20
background
BACK NEXT
Setting Individual Days (7 Day Commercial)
1. Press the PROG button. The display will switch to
programming mode. M (Monday) will appear and
the hour will flash.
2. Press SYSTEM to select HEAT or COOL.
3. Press DAY/TIME to select an individual day.
4. Press the SpeedBar
®
up or down to adjust the hour
for the OCCUPIED event. Press NEXT.
5. Press the SpeedBar up or down to adjust the
minute for the OCCUPIED event. Press NEXT.
6. Press the SpeedBar up or down to adjust the
temperature for the OCCUPIED event. Press NEXT.
7. Press the SpeedBar up or down to adjust the fan
setting for the OCCUPIED event. Press NEXT.
8. Repeat steps 4-7 for your UNOCCUPIED event.
9. If needed, repeat steps 3-7 to select other individual days.
10. If needed, repeat steps 2-9 to program the opposite mode (HEAT or COOL).
11. Press RETURN to exit.
BACK and NEXT are
secondary functions of the
PROG and HOLD buttons.
21 User Manual
background
4
Operating Your Thermostat
Setting the SYSTEM Control Mode
The System Control has 5 modes of operation – AUTO, COOL, OFF, HEAT and EMER. The mode can be selected
by pressing the SYSTEM button to scroll through the different modes.
NOTE: Depending on how your thermostat was configured, some system modes may not be available.
AUTO
The system will cycle between heating and
cooling automatically based on your program
set points. AUTO will be displayed with
either HEAT or COOL.
COOL Only your cooling system will operate.
OFF Heating and cooling systems are off.
HEAT Only your heating system will operate
EMER Operates a backup heat source
(Emergency Heat) for heat pump
systems only.
User Manual 22
background
Setting the FAN Control Mode
The Fan Control has 3 modes of operation – AUTO, ON, and PROG. The mode can be selected by pressing the
FAN button to scroll through the different modes.
NOTE: Depending on how your thermostat was configured, some fan modes may not be available.
AUTO The system fan will run only when your
heating or cooling system is running.
ON The system fan stays on.
PROG The system fan will function in the
AUTO or ON modes depending on your
program schedule.
23 User Manual
background
Setting the Temperature
Temporary Adjustment
Press the SpeedBar
®
up or
down
to adjust the current set temperature. If your
thermostat is running in 5-2 or 7 day programmable
mode, the set temperature will change back to your
original programmed settings when your next scheduled
change in temperature occurs.
Extended Adjustment – Press the HOLD button
so that HOLD appears in the display screen. Press the
SpeedBar up or down to adjust the current set temperature
(See Extended Hold Period, page 10).
NOTE: If this thermostat was configured to be non-
programmable, you will not have a HOLD option.
SpeedBar
User Manual 24
background
25 User Manual
Status Indicators
Status indicators appear in the display to let you know if your system is heating, cooling or off.
HEAT ON Heating system is running.
COOL ON Cooling system is running.
AUX Auxiliary stage of heating is running
(multi-stage systems only)
EMER
Emergency heating system is running
(heat pump systems only)
CHECK There is a potential problem with your system.
Contact a local service technician.
SERVICE User selectable service reminder for changing a
filter, UV air purifier bulb or humidifier pad
(See Service Monitors, page 10)
ADJ Temperature adjustment limit has been reached
Thermostat is connected to control module (flashes if connection is lost)
Thermostat battery is low (see section 6)
NO AC AC power to system has been lost
Status
Indicator
background
Communication Loss
If communication with a wireless device has been lost, the display screen will alternate between COMM LOSS
and the name of the device that has lost communication. See Table 1 for a list of possible device names.
The device will attempt to reconnect with the thermostat automatically, however you can also manually attempt
reconnection by pressing and holding the CONNECT button for 3 seconds on the device (see Installer Guide).
IDS1, IDS2, IDS3 or IDS4 Remote Indoor Sensor 1-4
ODS Remote Outdoor Sensor
HMS Remote Humidity Sensor
Control Module (see page 8)
CMOD
Table1
User Manual 26
background
27 User Manual
Remote Sensor - Low Batteries
If batteries become low in a wireless remote sensor, the display screen will alternate between LOW BATT and
the name of the sensor that has the low batteries. See Table 2 below for a list of possible sensor names. Replace
the batteries in the remote sensor as soon as possible (see wireless remote sensor instructions). After replacing
the batteries, the remote sensor will try to automatically reconnect. The reconnection may take up to 15 minutes.
IDS1, IDS2, IDS3 or IDS4 Remote Indoor Sensor 1-4 Requires 2 AA Alkaline Batteries
ODS Remote Outdoor Sensor Requires 2 AA Lithium Batteries
HMS Remote Humidity Sensor 24 VAC Powered - No Batteries
Table 2
background
Reset
Button
Program Event Indicators
Program event indicators appear in the display to let you
know what part of your current program is active.
In Residential Program Mode, MORN, DAY, EVE or NIGHT
will appear.
In Commercial Program Mode, OCCUPIED or UNOCCUPIED
will appear.
When the program event indicator is flashing, your program
has been temporarily bypassed and will resume at the
next scheduled event.
NOTE: You will not see a program event indicator while in
HOLD or Non-Programmable Mode.
Resetting the Thermostat
This thermostat provides you with a reset button that will
erase all of your user settings and programming.
The reset feature does not affect the Installer Settings.
To reset the thermostat, use a small object such as a
tooth pick or paperclip and gently press the button located
inside the small hole on the front of the thermostat housing
labeled “RESET ”.
NOTE: You cannot reset the thermostat if it is locked.
Program Event
Indicator
User Manual 28
background
29 User Manual
5
Additional Operation Features
Auto Changeover Mode
Auto Changeover mode is a feature enabled/
disabled in the
Installer Settings (see Installer
Guide). If enabled, it is selected
by pressing the
SYSTEM button until AUTO HEAT or AUTO COOL
appears in the display.
When Auto Changeover mode is enabled and
selected, the system automatically switches
between heating and cooling when the room
temperature meets the programmed heating or
cooling set points. To operate properly, the
thermostat requires a “dead band” setting to
eliminate program conflicts. The dead band is set
in the Installer Settings (See Installer Guide). The
default setting is 3° F. Therefore, you will not be able
to set your heat or cool temperature within 3° F of each other. If a setting is made in either heating or cooling
which violates the dead band, the opposite mode will adjust up or down automatically to maintain the pro-
grammed dead band spacing.
background
Adaptive Recovery Mode (ARM
)
Adaptive Recovery Mode is a feature enabled/disabled in the Installer Settings (See Installer Manual).
If enabled, the feature is automatically present while in programmable mode.
Adaptive Recovery Mode tries to reach your desired heating or cooling temperature at the time you have set in
your current program schedule, after a setback period. For example, if you set your heat down to 62° at night
and have a set point of 70° scheduled for 7:00 AM, the thermostat may turn on your heating system early in
order achieve a temperature of 70° by 7:00 AM.
This feature does not operate when the thermostat is in HOLD mode, if the program is temporarily overridden or
if emergency heat is selected on a multistage heat pump system.
User Manual 30
background
31 User Manual
DAY/TIME
Programmable Fan Mode
Programmable Fan Mode is selected by pressing
FAN until PROG appears in the display. It is only
available in programmable mode.
Programmable Fan Mode allows the user to run
the fan continuously during a selected program
event. To use this feature, select fan ON while
setting program events. (See “Setting Your
Program Schedule”, page 14).
Compressor Protection
Compressor protection is enabled/disabled
in the Installer Settings (See Installer Guide).
If enabled, this feature is automatically present in
cooling and/or heating modes.
This thermostat includes an automatic compressor protection delay to avoid potential damage to your system
from short cycling. This feature activates a short delay after turning off the system compressor.
Additionally, for multi-stage heat pump systems, this thermostat provides cold weather compressor protection by
locking out the compressor stage(s) of heating for a period of time after a power outage greater than 60 minutes.
This cold weather compressor protection can be manually overridden at any time by changing the system mode
to OFF momentarily, then back to HEAT.
background
DAY/TIME
BACK NEXT
Locking and Unlocking the Thermostat
Your 3-digit Lock Code is set in the “User Options”
portion of this manual (See “Setting User Options”,
page 9 and 12).
Once the code is set, the
thermostat can be locked or unlocked at any
time by entering that code.
To lock or unlock the thermostat, press and hold the
DAY/TIME and HOLD buttons together for 5 seconds.
The screen will change, displaying 000 and LOCK
will be flashing. Press the SpeedBar
®
or to
enter the first digit of your lock code and then press
NEXT* to advance to the next digit. Repeat this
process to enter the second and third digit of your
lock code. After entering the third digit, press RETURN.
*BACK and NEXT are secondary functions of the PROG and HOLD buttons.
User Manual 32
background
33 User Manual
If you entered a valid code the thermostat will be locked or unlocked
(depending on its previous state). When locked, the word LOCKED
appears in the display (Figure 1). If an invalid code is entered the
word
NO will briefly appear, indicating that an incorrect code was
entered (Figure 2).
Figure 1
Figure 2
background
AC Power Monitor
The AC Power Monitor feature is enabled in the Installer
Settings (See Installer Guide). If enabled, this feature will
automatically be present.
If your thermostat was hardwired (power provided from the system
with batteries as a backup) then the AC Power Monitor feature will
indicate when a loss of power to the thermostat has occurred by
displaying NOAC.
Indoor Remote Sensing
Indoor remote sensing is achieved by installing a Braeburn
®
wired or wireless remote indoor sensor and is
configured in the Installer Settings (See Installer Guide).
If a Braeburn indoor remote sensor was installed and properly configured in the Installer Settings, the thermostat
will sense temperature at a remote location or at a combination of a remote location and the thermostat location.
User Manual 34
background
35 User Manual
DAY/TIME
Outdoor Remote Sensing
Outdoor remote sensing is enabled by installing
a Braeburn
®
wired or wireless remote outdoor
sensor. No additional
configuration is required.
If a Braeburn outdoor remote sensor was installed
you may press the PROG and HOLD buttons at the
same time to view the outdoor temperature.
background
DAY/TIME
HUMID
Humidification and Dehumidification
If this thermostat was also equipped with
a wireless humidity sensor, it can be used to
control a whole house humidifier or dehumidifier.
Humidification can be controlled manually from
the thermostat or automatically when a outdoor
remote sensor is installed and configured in the
Installer Settings (See Installer Guide).
To view the current humidity level at the thermostat,
press the
DAY/TIME and RETURN buttons at the
same time (Figure 1). If humidification and
dehumidification
are not enabled, you will only see
the current humidity level.
If humidification is enabled you will see the current humidity
level along with the humidification set point (Figure 2). Press the
SpeedBar
®
up or down to adjust the humidification set point.
Figure 1
Figure 2
HUMID
User Manual 36
background
Figure 1
Figure 2
37 User Manual
If humidification and dehumidification are both enabled you will
first see the current humidity level along with the humidification
set point. Press the SpeedBar
®
up or down to adjust the humidification
set point. Press DAY/TIME and RETURN again to display the
dehumidification
set point. Press the SpeedBar up or down to adjust
the dehumidification
set point (Figure 3). Press RETURN.
NOTE: If Automatic Humidity Control was enabled in the Installer
Options, the humidification set point may be automatically adjusted
to compensate for changes in outdoor temperature.
When there is a call for humidification the word HUMID
will appear in the screen (Figure 4). When there is a call for
dehumidification, the word DEHUMID will appear.
DEHUMID
HUMID
Figure 3
Figure 4
background
6
Thermostat Maintenance
Thermostat Cleaning
Never spray any liquid directly on the thermostat. Using a soft damp cloth wipe the outer body of the thermostat.
Never use any abrasive cleansers to clean your thermostat.
Changing the Batteries
This thermostat requires two (2) properly installed “AA
alkaline batteries to maintain the thermostat clock and to
provide power for the thermostat if 24 volt AC power is not
connected. (See Installer Manual).
If batteries become low, a battery indicator will appear
in the display. You should change your batteries immediately
when you see the low battery signal by following
these instructions.
1. Remove thermostat body by gently pulling it from base.
2. Remove old batteries and replace with new batteries.
3. Make sure to correctly position the (+) and (-) symbols.
4. Gently push thermostat body back onto base.
NOTE: We recommend replacing the thermostat batteries annually or if the thermostat will be unattended for
an extended period of time.
+
+
User Manual 38
background
Limited Warranty
When installed by a professional contractor, this product is backed by a 5 year limited
warranty. Limitations apply. For limitations, terms and conditions, you may obtain a full
copy of this warranty:
· Visit us online: www.braeburnonline.com/warranty
· Write us: Braeburn Systems LLC
2215 Cornell Avenue
Montgomery, IL 60538
5
YEAR
WARRANTY
LIMITED
Stor e reference.
Store this manual for futur
e reference.
www.braeburnonline.com
background
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
844-BLU-LINK (844-258-5465) (U.S.)
630-844-1968 (Outside the U.S.)
©2018 Braeburn Systems LLC • All Rights Reserved • Made in China. 7500-110-02
®
®