18
CLEANING AND MAINTENANCE
ATTENTION: Please shut off the unit and unplug from the mains before cleaning or
performing any maintenance.
CLEANING THE SURFACE
Clean the heater with a duster or a soft wet cloth.
Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may
cause irreversible damage. Make sure no water enters the control panel or gaps in the
casing.
Do not run the unit until completely dry.
Place the heater in its original box or cover to protect it from dust when not in use.
Store it in a cool dry place.
TROUBLESHOOTING
Do not repair or disassemble the unit by yourself, unauthorized repair attempts will
invalidate the warranty and may cause bodily harm.
Issue
Possible Reason
Solution
No power
1. Power cord is unconnected
2. There is no power from socket
3. The power switch on the rear of the unit
is turned off.
1. Connect the power cord
2. Check socket is turned on
3. Ensure the power switch on
the rear of the unit is in the on
position
Odour
emission
from unit
1. New unit. When the unit is used for the
first time the fan motor may produce and
odour which will dissipate within a week of
use
1. No action required
Strong
vibrations
and noise
1. Unit is not placed on a flat surface
2. Unit may be damaged
1. Place on a flat surface. May
put an anti-vibration mat
underneath
2. If the heater is damaged
discontinue use and contact the
service centre.
If the above solutions do not resolve the problem please contact the service centre.
TECHNICAL DATA
Model no.
EPHAL2000W
Voltage
220V-240V 2.0kW
Frequency
50 / 60 Hz
Max power
1000W/1800-2000W
IP Rating
IP24
Product Dimensions
920X240X430MM