INSTALLATION INSTRUCTIONS
CONNECTING ICE MAKER TO DRAIN
Drain Type Drain Drain Height Operation Instructions
Continuous
Drain Mode
Note: This
mode requires
the drain hose
outlet to be
below the
drain-hose inlet
on the unit to
perform as re-
quired. This will
help keep wa-
ter from owing
back into the
unit and poten-
tially owing
onto the oor
causing water
damage.
• Excess water
will drain out
of the contin-
uous outlet
on the back of
the unit using
the force of
gravity.
The height of the drain
hole in the room
100 mm (3-15/16”)
Reference Fig. C, D and E.
Drain nut and drain pump switch Condi-
tion
Drain nut (front) (3) + drain seal (front) (4) Closed
Drain nut (back) (7) + drain seal (back) (6) Open
Drain cap (11) Closed
Drain cap (12) Open
Drain pump switch (8) OFF
1. Please ensure the drain nut and switch are
in the above condition;
2. Connect one side of the drain pipe to the
continuous drain outlet and the other side
to the drain hole. The drain must slop
downwards towards the drain hole. Please
ensure the connection is tight.
Drain Pump
Mode
Note: Pump will
not work during
a power out-
age. If the drain
hose becomes
twisted and
water cannot
drain, your ice
maker will not
work.
• Excess water
will be drained
out by the in-
ternal pump.
The height of the drain
hole in the room is be-
tween 101 mm ~ 1500
mm (3-15/16” ~ 59”)
Reference Fig. C, D and E.
Drain nut and drain pump switch Condi-
tion
Drain nut (front) (3) + drain seal (front) (4) Closed
Drain nut (back) (7) + drain seal (back) (6) Open
Drain cap (11) Open
Drain cap (12) Closed
Drain pump switch ON
1. Please ensure the drain nut and switch are
in the above condition;
2. Using a drain pipe no longer than 16 feet
(192”), connect one side to the drain pump
outlet and the other side to the drain hole.
≤ 100 mm
≤ 3-15/16”
101mm~1500mm
3-15/16”~59”
1
6
f
e
e
t
1
9
2
6
The length of drain pipe cannot exceed 16
feet (192”) in order to prevent water from
coming back.