FIGURE 3. VALVE POSITIONS
FIGURE 4. MANUAL LIGHTING ACCESS
FIGURE 5. BURNER SITE WINDOW
Manual Lighting Procedure:
Open the pizza oven doors and position
on the sides of the oven.
Make sure the main burner valve is the
OFF position (See Figure 3.).
Turn the main gas supply on and wait 15
seconds.
Turn the pilot valve to the on position.
Insert a barbeque lighter into the hole
located behind the wing door on the face
of the pizza oven (see Figure 4).
Visually inspect to see that the pilot tube
is lit.
Turn the main burner valves on to the
desired temperature setting. (See general
operating procedures for guidelines on
how to determine ideal temperature
settings). Ignition should take place within 4 to 5 seconds. Verify that the burners are lit by
looking through the site widows on the face of the oven (See Figure 5.). If the burners do not
light within this time, turn the temperature knob to the OFF position and wait 5 minutes for the
gas to dissipate before trying again. If the appliance will not light after multiple attempts, refer
to the troubleshooting section of this manual.