26
Measurement
EE
appears if the measurement could
not be performed properly (see chapter
10 “Error messages/troubleshooting”).
Repeat the measurement.
Now select the desired user memory by pressing the
M1 or M2 memory buttons. If you do not select a user
memory, the measurement is stored in the most re-
cently used user memory. The relevant or symbol
appears on the display.
Press the START/STOP button to switch off the
blood pressure monitor. The measurement is then
stored in the selected user memory.
If the device is not switched off manually, it will switch
off automatically after approx. 1minute.
If Bluetooth
®
data transfer has been activated, data is
transferred after having confirmed the user memory and
pressing the START/STOP button .
The Bluetooth
®
symbol flashes on the display. The
blood pressure monitor now attempts to connect to the
app for approx. 30 seconds.
The Bluetooth
®
symbol stops flashing as soon as a
connection is established. All measurement data is
automatically transferred to the app. Once the data has
been successfully transferred, the device switches off.
If the data transfer was unsuccessful, “EE7” appears on
the display.
Measurement
If a connection to the app cannot be established after
30 seconds, the Bluetooth
®
symbol goes out and the
blood pressure monitor switches off automatically after
1 minute.
Please note that you must add the blood pressure
monitor in “My devices” in the “beurer HealthManag-
er” app to enable data transfers. The “beurer Health-
Manager” app must be active to allow data transfers.
If the latest data is not displayed on your smart-
phone, repeat the data transfer as described in
chapter 8.
If you forget to turn off the blood pressure monitor, it will
switch off automatically after a further 30seconds. In
this case too, the value is stored in the selected or most
recent user memory and the data is transferred if Blue-
tooth
®
data transfer has been activated.
Wait at least 5 minutes before taking an-
other measurement.
6. Evaluating results
Cardiac arrhythmia:
This device can identify potential disruptions of the heart
rhythm when measuring and if necessary, indicates this after
the measurement with the symbol
.
This can be an indicator for arrhythmia. Arrhythmia is a con-
dition in which the heart rhythm is abnormal because of flaws
in the bioelectrical system that regulates the heartbeat. The