Faber INPL4822SS Inca Pro Plus Halogen

Installation Instructions - Page 2

For INPL4822SS.

PDF File Manual, 20 pages, Read Online | Download pdf file

INPL4822SS photo
Loading ...
Version 10/12 - Page 2
VENTING REQUIREMENTS
Determinewhichventingmethodisbestforyourapplication.
Ductworkcanextendeitherthroughthewallortheroof.
Thelengthoftheductworkandthenumberofelbowsshouldbe
kepttoaminimumtoprovideefcientperformance.Thesize
oftheductworkshouldbeuniform.Donotinstalltwo
elbows together. Use duct tape to seal all joints in the ductwork
system.Usecaulkingtoseal exteriorwall oroor opening
around the cap.
Flexible ductwork is not recommended. Flexible ductwork
creates back pressure and air turbulence that greatly
reduces performance.
Makesurethereisproperclearancewithinthewalloroorfor
exhaustductbeforemakingcutouts.Donotcutajoistorstud
unlessabsolutelynecessary.Ifajoistorstudmustbecut,then
a supporting frame must be constructed.
FORMORESPECIFICDUCTWORKINFORMATION,GO
TOPAGE7.
WARNING - To Reduce The Risk Of Fire, Use Only Metal
Ductwork.
ELECTRICAL REQUIREMENTS
A120volt,60HzAC-onlyelectricalsupplyisrequiredonasepa-
rate 15 amp fused circuit. A time-delay fuse or circuit breaker
isrecommended.Thefusemustbesizedperlocalcodesin
accordancewiththeelectricalratingofthisunitasspecied
ontheserial/ratingplatelocatedinsidetheunitneartheeld
wiring compartment. THIS UNIT MUST BE CONNECTED
WITHCOPPERWIREONLY.Wiresizesmustconformtothe
requirementsoftheNationalElectricalCode,ANSI/NFPA70
-latestedition,andalllocalcodesandordinances.Wiresize
and connections must conform with the rating of the appliance.
Copiesofthestandardlistedabovemaybeobtainedfrom:
National Fire Protection Association
Batterymarch Park
Quincy,Massachusetts02269
This appliance should be connected directly to the fused
disconnect (or circuit breaker) through exible, armored or
nonmetallic sheathed copper cable. Allow some slack in the
cable so the appliance can be moved if servicing is ever nec-
essary.AULListed,1/2"conduitconnectormustbeprovided
ateachendofthepowersupplycable(attheapplianceand
atthejunctionbox)
•VentingsystemMUSTterminateoutsidethe
home.
•DONOTterminatetheductworkinanatticor
other enclosed space.
•DONOTuse4"laundry-typewallcaps.
•Flexible-typeductworkisnotrecommended.
•DONOTobstructtheowofcombustionand
ventilation air.
•Failuretofollowventingrequirementsmayresult
inare.
Whenmakingtheelectricalconnection,cuta11/4"holeinthe
wall. A hole cut through wood must be sanded until smooth. A
hole through metal must have a grommet.
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, do not use this fan with any solid-state speed
control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOL-
LOWING: Use this unit only in the manner intended by
the manufacturer. If you have any questions, contact the
manufacturer.
Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
WARNING - TO REDUCE THE RISK OF SHOCK: This fan
must be installed with an isolating wall control/switch.
CAUTION: For General Ventilating Use Only. Do Not Use To
Exhaust Hazardous or Explosive Materials and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOL-
LOWING: Installation Work And Electrical Wiring Must
Be Done By Qualied Person(s) In Accordance With All
Applicable Codes And Standards, Including Fire-Rated
Construction.
Sufcient air is needed for proper combustion and exhaust-
ing of gases through the ue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer's guideline and safety standards
such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
WARNING
•Electricalgroundisrequiredonthisrangehood.
•Ifcoldwaterpipeisinterruptedbyplastic,
nonmetallicgasketsorothermaterials,DONOT
use for grounding.
•DONOTgroundtoagaspipe.
•DONOThaveafuseintheneutralorgrounding
circuit. A fuse in the neutral or grounding circuit
could result in electrical shock.
•Checkwithaqualiedelectricianifyouareindoubt
as to whether the rangehood is properly grounded.
•DONOTusethisappliancewithanysolidstatefan
speed control device.
•Failuretofollowelectricalrequirementsmayresult
inare.
WARNING
For residential use only.
!
!
Cold Weather installations
Anadditionalbackdraftdampershouldbeinstalledtominimize
backwardcoldairowandanonmetallicthermalbreakshould
beinstalledtominimizeconductionofoutsidetemperatures
aspartoftheventsystem.Thedampershouldbeonthecold
airsideofthethermalbreak.Thebreakshouldbeascloseas
possible to where the vent system enters the heated portion
of the house.