oPERAtING yoUR INFUSER™ ESPRESSo MACHINE
UNdER ExtRACtEd ZoNE
During extraction, the gauge needle when
positioned in the lower zone, indicates
the espresso has been extracted with
insufcient pressure.
This occurs when the water ow through
the ground coffee is too fast and results in
an under extracted espresso that is watery
and lacks crema and avour.
Causes for under extraction include the grind
being too coarse and/or insufcient coffee in
lter and/or under tamping.
ovER ExtRACtEd ZoNE
The gauge needle, when positioned in the
upper zone during extraction, indicates the
espresso has been extracted with too much
pressure.
This occurs when the water flow through the
ground coffee is too slow and results in an
over extracted espresso that is very dark and
bitter with a mottled and uneven crema.
Causes for over extraction include the grind
being too fine and/or too much ground
coffee in filter and/or over tamping.
tExtURING MILk
The Smooth Infuse™ comes with a
commercial style steam wand.
tExtURING MILk
Turn the STEAM/HOT WATER
selector dial to the steam position.
The STEAM/HOT WATER light will
ash to indicate the machine is heating
to create steam.
When the STEAM/HOT WATER light
stops ashing the steam wand is ready
for use.
Before inserting the steam wand into
the milk, pause the steam by returning
the dial back to the STANDBy position.
This will avoid the milk splashing out of
the jug (this pause function lasts for 6
seconds before exiting steam mode).
Insert the wand into the milk and return
the dial back to the steam position to
texture milk.
To stop the steam return the Steam dial
to the STANDBy position and remove
the jug.
oPERAtING yoUR INFUSER™ ESPRESSo MACHINE
RESEttING dEFAULt voLUMES
To reset the machine to the default 1 CUP
and 2 CUP shot volumes, press and hold the
PROGRAM button until the machine beeps
three times. Release the PROGRAM button.
The machine will return to its original
default setting.
NotE
Default settings: 1 CUP shot volume is
approx. 30ml. 2 CUP is approx. 60ml.
MANUAL ESPRESSo
Press and hold the 1 CUP or 2 CUP button.
Release the button once sufficient espresso
has been extracted into the cup.
OR
NotE
For optimal flavour when using a
1 CUP filter, you should extract approx.
30ml. When using a 2 cup filter, you
should extract approx. 60ml.
WARNING
The metal parts of the portafilter will
be very hot.
ESPRESSo PRESSURE GAUGE
LoW PRESSURE PRE-INFUSIoN
The gauge needle will be positioned in
the pre-infusion zone at the start of the
extraction indicating the machine is in
low pressure pre-infusion mode.
The low pressure pre-infusion gradually
increases water pressure to gently expand
grinds for an even extraction before
increasing to full pressure.
IdEAL ESPRESSo ZoNE
During extraction, the gauge needle when
positioned in the middle zone, indicates
the espresso will be extracted at the ideal
pressure.