10 49-5000434 Rev. 2
Installation Instructions
INSTALLATION INSTRUCTIONS
2. STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly. To adjust for this,
attach a piece of wood to the sill.
WOOD PIECES
WIDTH: 2Ǝ
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place
DSLHFHRIZRRGRQWKHVLOOWRPDNHLWƎKLJKHU
than the top of the storm window frame or the
vinyl frame.
Attach securely with nails or screws provided by
the installer.
ƎKLJKHU
than storm
window
frame
Storm window
frame
Wood
Sill
ƎKLJKHU
than vinyl frame
(on some windows)
Vinyl frame
3. PREPARE THE AIR
CONDITIONER
A. Pull down the front panel and remove the filter.
Remove the front panel by lifting up at an angle.
B. Remove the four front screws. Save them for
reinstalling the front housing.
C. Grasp the lower corners of the grille while
pressing in on the case sides with your finger
tips. Pull out to release and lift it up.
NOTE: Do not pull the bottom edge toward you
PRUHWKDQƎRU\RXPD\GDPDJHWKHWDEVRIWKH
grille.
D. When the front grille is removed the control
panel will still be attached by a harness. Turn
the grille around so you can see the back side
of the grille. Remove the 2 screws to separate
the control panel housing from the grille. NOTE:
%HVXUHWRVDYHWKHVHVFUHZV<RXZLOOQHHG
them later in the installation.
Remove Screws
1. WINDOW REQUIREMENTS
These instructions are for a standard
double-hung window. You will need to modify
them for other types of windows.
The air conditioner can be installed without the
accordion panels if needed to fit in a narrow
window. See the window opening dimensions.
All supporting parts must be secured to firm
wood, masonry or metal.
The electrical outlet must be within reach of the
power cord.
A
(With accordion panels)
%
Model A B
AEG14, AEG18 ´PLQ 26”- 41”
AEG24 ´PLQ 30”- 41”
Loading ...
Loading ...