Gaggenau RB472701 400 Series 30 Inch Counter Depth Bottom Freezer Refrigerator with 16.2 cu. ft. Total Capacity, 4.9 cu. ft. Freezer Capacity

Operating instructions - Page 25

For RB472701. Series: 400 Series
Also, The document are for others Gaggenau models: RY492*, RB492*, RB472*

PDF File Manual, 83 pages, Read Online | Download pdf file

RB472701 photo
Loading ...
Loading ...
Loading ...
25
Ice maker
Fault Possible cause Remedial action
The ice maker doesn’t work. Ice maker is not connected to the mains
supply.
Call customer service.
Ice maker does not contain any fresh
water.
Ensure that the water is properly connected.
The freezer compartment temperature is
too warm.
Check freezer compartment temperature and,
if required, set slightly colder.
The ice maker does not make
enough ice or the ice is
deformed.
The appliance or ice maker has only just
been switched on.
Approx. 24 hours is needed until ice production
starts.
A lot of ice has been taken. Approx. 24 hours is needed until the ice cube
container is filled again.
Low water pressure. Connect the appliance to the stipulated water
pressure only (see chapter Connecting appli-
ance, section Water connection).
The water filter is bunged up or used. Change the water filter.
Temperature in the freezer compartment
is too warm.
Set temperature slightly colder in the freezer
compartment.
Ice cubes have accumulated on the rear
panel of the ice cube container.
Distribute ice cubes in the ice cube container. If
ice cubes are stuck to each other, loosen with
a blunt implement.
The ice maker does not make any
ice.
The ice maker is switched off. Switch the ice maker on at the control panel.
The appliance is not supplied with water. Contact the installer or the water supply com-
pany.
Water supply has kinks. Turn off the water supply at the shut-off tap.
Smoothen out the kinks, exchange where nec-
essary.
Low water pressure. Connect the appliance to the stipulated water
pressure only (see chapter Connecting appli-
ance, section Water connection).
Temperature in the freezer space is too
warm.
Set temperature slightly colder in the freezer
compartment.
Ice cube container is not properly
inserted.
Check the position, re-insert where necessary.
Incorrect shut-off tap installed. Incorrect taps can cause low water pressure
and damage to the appliance.
Ice forms in the inflow hose
to the ice maker.
Low water pressure. Connect the appliance to the stipulated water
pressure only (see chapter Connecting appli-
ance, section Water connection).
Shut off tap incorrectly opened. Open shut off tap fully.
Water runs from the appliance. The water connection hose is not prop-
erly sealed.
Replace the hose with a manufacturer’s origi-
nal part.
Incorrect shut-off tap installed. Incorrect taps can cause low water pressure
and damage to the appliance.
Loading ...
Loading ...
Loading ...