Rear Ducted Installation for 2 motor Rangehood


The Electrical Connector must be
removed first before converting the
hood to Rear Ducting mode.
The Electrical Connector is always
on the left of left Motor Group.
For a rear ducting installation the
motor needs to be unsecured by first
removing the 16 screws as shown.
Once the screws are removed,
extract the blower from the body
of the Hood and position it so the
transition opening is facing to the
rear wall (from the back remove and
rotate 180 degrees to the left, and
then ip it back 90 degrees as shown
in the diagram).
Once the blower is in place re-install
the 16 screws to fasten the motor to
the Hood body.
Disconnect the 2 Electrical Connector,
one from the left motor goup and
one from the right motor Grpoup, by
depressing the tabs with your hand and
also using light force on one tab with a
at head screwdriver.
Reconnect the Connector to the
blower.
Attention: The longhest cable with
connector is always for Left motor
Group, and the shortest cable with
connector is always for Right motor
Group.
Reconnect the Electrical Connector
on the left of left Motor Group.