42
MAINTENANCE
ENGLISH
Replacing the Water Filter
It is recommended that you replace the water
filter:
Ap
ü
proximately every six
months.
When the water filter
ü
indicator turns on.
When the water
ü
dispenser output
decreases.
When the ice cubes are smaller than normal.
ü
1
Remove the old water filter.
Lower or remove the
ü
top left shelf to allow the
water filter to rotate all
the way down.
Press the push button
ü
to open the water filter
cover.
! " # $ % & ' ' ( ! ) $
* +
' ' , ! - ! -
. / . . 0 1 2 3 . 4
5 . . / 4 5 . /
6 ) ) 7 8 , )
+ +
) 7
. 9 2
Pull the water
ü
filter downward and
pull out. Make sure to
rotate the filter down
completely before pulling
it out of the manifold
hole.
2
Replace with a new
water filter.
Take the new water filter out of its packing
ü
and remove the protective cover from the
o-rings. With
water filter tabs
in the horizontal
position, push
the new water
filter into the
manifold hole
until it stops.
Rotate the water filter up
ü
into position and close
the cover. The cover
will click when closed
correctly.
3
After the water filter is replaced,
dispense 2.5 gallons of water (flush for
approximately 5 minutes) to remove
trapped air and contaminates from the
system. Do not dispense the entire 2.5
gallon amount continuously. Depress and
release the dispenser pad for cycles of 30
seconds ON and 60 seconds OFF.
4
Water Filter Bypass Plug
Keep the water
filter bypass plug.
You MUST use
the water filter
bypass plug when a
replacement water
filter cartridge is not
available.
Water Filter
Bypass Plug
CAUTION
DO NOT operate refrigerator without
water filter or water filter plug installed.
NOTE
To purchase a replacement water filter:
ü
- Visit your local dealer or distributor
- Web: Find Parts & Accessories from
Support section of lg.com
- Call : 1-800-243-0000 (USA)
1-888-542-2623 (Canada)

43
MAINTENANCE
ENGLISH
Performance Data Sheet
Model: LG ADQ36006101-S Use Replacement Cartridge: ADQ36006101
The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system as specified in
NSF/ANSI Standard 42 and Standard 53.
System tested and certified by NSF International against NSF/ANSI Standard 42
and Standard 53 for the reduction of substances listed below.
Contaminant
Reduction
Average
Influent
NSF specified
Challenge
Concentration
Avg %
Reduction
Average
Product Water
Concentration
Max
Permissible
Product Water
Concentration
NSF
Reduction
equirements
NSF Test
Report
Chlorine Taste and
Odor
2.1 mg/L 2.0 mg/L ± 10% 97.2% 0.06 mg/L N/A ≥ 50% J-00049247
Nominal Particulate
Class I, , ≥ 0.5 to <
1.0 µm
5,600,000 pts/
mL
At least 10,000
particles/mL
98.7% 73,000 pts/ml N/A ≥ 85% J-00049282
Asbestos 190 MFL
10
7
to 10
8
MFL;
fibers greater
than 10 µm in
length
>99% < 1MLF N/A ≥ 99% J-0004928
Atrazine 0.0094 mg/L
0.009 mg/L
± 10%
94.7% 0.00005 mg/L 0.003 mg/L N/A J-00049293
Benzene 0.016 mg/L
0.015 mg/L
± 10%
96.7% 0.005 mg/L 0.005 mg/L N/A J-00049300
Carbofuran 0.08 mg/L
0.08 mg/L
± 10%
98.1% 0.002 mg/L 0.04 mg/L N/A J-00049294
Lindane 0.002 mg/L
0.002 mg/L
± 10%
98.2% 0.00004 mg/L 0.0002 mg/L N/A J-00051975
P-Dichlorobenzene 0.22 mg/L
0.225 mg/L
± 10%
99.8% 0.0005 mg/L 0.075 mg/L N/A J-00049298
Toxaphene 0.014 mg/L
0.015 mg/L
± 10%
93% 0.001 mg/L 0.003 mg/L N/A J-00049302
2,4-D 0.213 mg/L
0.210 mg/L
± 10%
95.2% 0.009 mg/L 0.07 mg/L N/A J-00049284
Lead pH @6.5 0.150 mg/L
0.15 mg/L
± 10%
>99.3% 0.001 mg/L 0.010 mg/L N/A J-00051974
Lead pH @8.5 0.150 mg/L
0.15 mg/L
± 10%
>99.3% 0.001 mg/L 0.010 mg/L N/A J-00049277
Mercury @ pH 6.5 0.0059 mg/L
0.006 mg/L
± 10%
96.1 0.0002 mg/L 0.002 mg/L N/A J-00053886
Mercury @ pH 8.5 0.0058 mg/L
0.006 mg/L
± 10%
90.1 0.0006 mg/L 0.002 mg/L N/A J-00051972
Cyst*
120,000
cysts/L
Minimum 50,000
cysts/L
99.99% <1 cyst/L N/A ≥ 99.95% J-00049281
* Based on the use of Cryptosporidium parvum oocysts.

44
MAINTENANCE
ENGLISH
It is essential that the manufacturer’s
recommended installation, maintenance and
filter replacement requirements be carried out
for the product to perform as advertised.
Replacement Cartridge: ADQ36006101
For estimated costs of replacement elements
please call USA 1-800-243-0000
CANADA 1-888-LGCANADA (24 hours per
day/7 days per week) or visit our website at
www.lg.com
3M is a trademark of 3M Company.
NSF is a trademark of NSF International.
© 2009 3M Company. All rights reserved.
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (1.9 lpm)
Water Supply Potable Water
Water Pressure 20 -120 psi (138 - 827 kPa)
Water Temperature 33°F - 100°F (0.6°C - 38°C)
NOTE
While the testing was performed
ü
under standard laboratory conditions,
actual performance may vary.
WARNING
To reduce the risk associated with choking:
Do not allow children under 3 years of age
ü
to have access to small parts during the
installation of this product.
To reduce the risk associated with the
ingestion of contaminants:
Do not use with water that is
ü
microbiologically unsafe or of unknown
quality without adequate disinfection before
or after the system. Systems certified for
cyst reduction may be used on disinfected
water that may contain filterable cysts. EPA
Establishment # 070595-MEX-001
CAUTION
To reduce the risk associated with property
damage due to water leakage:
Read and follow. Use Instructions before
ü
installation and use of this system.
Installation and use MUST comply with all
ü
state and local plumbing codes.
Do not install if water pressure exceeds
ü
120 psi (827 kPa). If your water pressure
exceeds 80 psi, you must install a
pressure limiting valve. Contact a plumbing
professional if you are uncertain how to
check your water pressure.
Do not install where water hammer
ü
conditions may occur. If water hammer
conditions exist you must install a water
hammer arrester. Contact a plumbing
professional if you uncertain how to check
for this condition.
Do not install on hot water supply lines.
ü
The maximum operating water temperature
of this filter system is 100°F (37.8°C).
Protect filter from freezing. Drain filter when
ü
temperatures drop below 40°F (4.4°C).
The disposable filter cartridge MUST be
ü
replaced every 6 months, at the rated
capacity or if a noticeable reduction in flow
rate occurs.
Protect from freezing, remove filter
ü
cartridge when temperatures are expected
to drop below 33° F.
Do not install systems in areas where
ü
ambient temperatures may go above
110° F (43.3° C).
Where a backflow prevention device is
ü
installed on a water system, a device
for controlling pressure due to thermal
expansion must be installed.
Ensure all tubing and fittings are secure and
ü
free of leaks.
Manufactured for LG®Electronics by CUNO
Incorporated 400 Research Parkway Meriden,
CT 06450 U.S.A Worldwide: 203-237-5541
www.cuno.com

45
MAINTENANCE
ENGLISH