FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Wa ter In let
Air Cooled Models: Connect to a water supply
that is cold and potable. Use
3
8
" O.D. copper
tubing, and connect to the single
3
8
" male flare at
the back of the cabinet. This connection supplies
water to both ice making systems. Install a hand
valve near the machine to control the water supply.
Water Treatment: In most areas, a water filter of
some type will be useful. In areas where the water
is highly concentrated with minerals the water
should be tested by a water treatment specialist,
and the recommendations of the specialist
regarding filtration and/or treatment should be
followed.
Drains
Air Cooled Models: Connect a drain tube to the
one ¾" FPT gravity drain fitting at the back of the
cabinet (used or both ice making systems). A ¼
inch per foot fall is the minimum pitch for the drain
tubing. There MUST be a vent at the highest point
of the drain line, and the ideal drain receptacle is a
trapped and vented floor drain.
Use only ¾" rigid tubing.
Storage Bin: Connect a separate gravity type
drain tube, similar to the air cooled drain. Insulation
of this drain line is recommended.
FME2404 or NME1854
January 2012
Page 6
AIR COOLED
MODELS
HAND
VALVE
FIELD
SUPPLIED
FILTER
WATER
INLET
VENTED
DRAIN