Loading ...
Loading ...
Loading ...
For The Installer: Environmental Limitations
The ice machine must be installed indoors in a
controlled environment.
Minimum Maximum
Air Temp 50
0
F. 100
0
F.
Water Temp 40
0
F. 100
0
F.
Water Pressure 20 PSI 80 PSI
Voltage (60 Hz) 103.5 126.5
Voltage (50 Hz) 207 253
Operating the ice machine outside of the above
limitations, or outdoors, is potentially damaging to
the machine, and it is misuse of the machine. This
may void the warranty.
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL, NSF, and other agencies.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and design are subject to change
without notice.
Airflow on air cooled models:
·
Intake through the right grill.
·
Exhaust from the left grill.
Do not install where this air flow is blocked.
The AFE400 has a removable cabinet. When
installed, the machine should have some extra
clearance (1/8") on the left and right sides so that
the cabinet may be easily removed when the
machine is in place.
AFE400
February 2009
Page 3
AIR OUT
AIR IN
Loading ...
Loading ...