Installation
English 25
STEP 3 Connect the electrical wiring
First, read through the “Electrical requirements” section, and follow these steps.
3-wire system
A B C L2 L1
D
E
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E.
3
/
4
” (1.9 cm) UL-listed strain relief
1. Loosen or remove the screws from the
center terminal block.
2. Connect the neutral wire (white or
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
3. Connect the other wires to outer
terminal block screws. Tighten the
screws.
4. Tighten the strain relief screws.
5. Insert the terminal block cover into the
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
To convert from the 4-wire system
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
Ring-type terminals are recommended.
If using strap terminals, make sure they
are tightened.
Before Installing the Dryer, conrm
240 V is present between L1 and L2 at
the power receptacle. If the Voltage is
low, it may not dry properly. Review
the “Electrical requirements” section on
page 19 if needed.