Installation
13 Install the Protector System
®
(continued)
OPTION B WALL INSTALLATION
If additional clearance is needed an extension bracket(notprovided) or wood blockscan be used.
Make sure each bracket has the same amount ofclearance so theywill align correctly.
1. Position the sensor bracket againstthe wall with the curved arms facing the door. Make sure
there is enough clearance for the beam to be unobstructed. Mark holes.
2. Drill 3/16 inch pilot holes for each sensor bracket and attach the sensor bracketsto the wall
using lag screws (not provided).
3. Slide the carriage boltinto the slot on each sensor.
4. Insert the boltthrough the hole in the sensor bracket and attach with the wing nut. The lenses
on both sensors should point toward each other.Make sure the lens is not obstructed by the
sensor bracket.
(Not provided)
No more than
6 inches (15 cm)
1
2
Inside
G
arage
Wall
(Not provided)
Lens
Carriage Bolt
1/4"-20 x 1/2"
Wing Nut
1/4"-20
3
4
OPTION C FLOOR INSTALLATION
Use an extension bracket (not provided) or wood block to raise the sensor bracketif needed.
1. Carefully measure the position of both sensor bracketsso they will be the same distance from
the wall and unobstructed.
2. Attach the sensor brackets to the floor using concrete anchors (not provided).
3. Slide the carriage boltinto the slot on each sensor.
4. Insert the boltthrough the hole in the sensor bracket and attach with the wing nut. The lenses
on both sensors should point toward each other.Make sure the lens is not obstructed by the
sensor bracket.
I
nsid
e
G
arage
Wa
l
l
(Not provided)
1 2
Carriage Bolt
1/4"-20 x 1/2"
Wing Nut
1/4"-20
3
4
Loading ...
Loading ...
Loading ...