Rinnai Australia 11 Installation Manual
COMMUNICATION CABLE
CONNECTING COMMUNICATION CABLES TO THE WATER HEATER
Communication cables connect the water heater to any wired water controllers and the wireless
transceiver and operate at an extra low voltage (12 Volts DC) which is supplied from the water heater.
Communication cables are supplied with the wired controllers (15m) and the transceiver (1.5m) and
are fitted with spade terminals for connection to water heater. Up to two cables can be connected
directly to the ‘Ezi connect’ cable connector at the water heater. Extension cables are available from
Rinnai. Alternatively, two core sheathed (double insulated) flex with minimum cross sectional area of
0.5mm² may be used. Cable lengths must not exceed 20 metres.
To connect up to two cables to the ’Ezi connect’ cable connector
DO NOT attempt to connect cables to the 'Ezi connect' cable connector at the water
heater unless the electric power to the water heater is switched ‘off’ otherwise damage
to electrical components may occur.
If your water heater is not fitted with an 'Ezi connect' cable connector, installation
must be completed by a qualified and licensed tradesperson.
1. Isolate the electric power supply by switching the power point off and removing the power plug of
the water heater from the electric power socket.
2. Remove the retaining screw of the 'Ezi connect' cable connector at the base of the appliance.
3. Swing the 'Ezi connect' cable connector door open and thread the cable through the weather seal
of the cable access hole in the direction shown allowing sufficient cable length so that the
sheath of the cable can be secured with cable clamp supplied with the transceiver.
4. Loosen screw terminals and and connect the cable spade connectors to these terminals
and re-tighten. Polarity is not important, either wire colour can be connected to either terminal.
5. Return the 'Ezi connect' cable connector to the original position taking care not to damage cable
wires in the process and replace the retaining screw .
To connect three or four cables to the 'Ezi connect' cable connector, consult the
“CONNECTING WATER CONTROLLERS” section of the water heater Operation /
Installation manual supplied with the water heater.
CAUTION
A
B
C
D E
A
A
B
A
C
E
D
B
'Ezi connect' cable connector for water heater models:
INFINITY 26, 26 Plus, 20, 16, V1500, V1200.
HD 200e (REU-VM2630WC).
'Ezi connect' cable connector for water heater models:
INFINITY 32, 26i, EVIROSMART
HD 250e, 200e (REU-VRM2632WC), 200i