Bolt to Floor Guide
Introduction
Life Fitness Family of Brands designs its products to be stable when used as designed. Because strength training is dynamic, we
cannot predict how users will ultimately use the products in all circumstances. Therefore, Life Fitness Family of Brands recommends
that strength training equipment be secured to a solid, level surface to stabilize and eliminate rocking or tipping over.
Each new unit shipped comes with a multi-language hangtag stating the importance of bolting the unit down as a safety precaution.
It is the facility’s responsibility to adhere to local and regional building codes.
Delivery and Installation Tips
All Anchors
Fasteners must have minimum embedment in concrete floor, not including screed, regardless of wood/tile/rubber over sub-floor.
(See Anchor Types for maximum sub-floor thickness between unit and concrete to equipment foot must be made of flooring or
other material (i.e. no air gaps)).
DO NOT reuse fasteners. Static and Dynamic anchors are designed for one-time use only.
Factor in equipment’s feet height when selecting fastener length.
Factor in flooring thickness when selecting fastener length.
It is also recommended to drill an additional 1/2” (12.7 mm) of depth beyond the length of the fastener being used to ensure that
debris does not block the entry of the anchor.
Minimum concrete compressive strength: 3000 psi (20 N/mm2).
Anchoring
All anchors must have a minimum embedment into concrete, regardless of wood/tile/rubber/screed over sub-floor.
Dynamic anchors must have a minimum embedment depth in concrete to ensure maximum security and pull out force. See Anchor
Types for embedment depth minimums.
Building Codes
It is the facility’s responsibility to adhere to local and regional building codes. Please verify with the customer to ensure that they are
aware of this.
Carpeting
If bolted down to carpet flooring, be sure to use a box cutter knife to cut the carpet threads around each foot. This will help avoid the
carpet threads from being wrapped around and pulled by the drill bit.
Competitor Product
The bolt down guidelines and procedures for Cybex products were determined by the company’s Engineering and Installation
Development groups. These guidelines include which anchors to use and positioning of the anchors are required for Cybex product.
Cybex does not have that level of specification or engineering input for competitive product.
Cybex installation teams are not permitted to anchor competitor equipment.
Drilling
It is also recommended to drill an additional 1/2” (12.7 mm) of depth beyond the length of the fastener being used to ensure that
debris does not block the entry of the anchor.
This can be done by marking your drill bit with a piece of tape.
While it is recommended that a vacuum be used to clean up debris, this will not account for all the debris that will settle at the
bottom of the drilled hole.