30 PLASMA MONITOR
Miscellaneous
Set ID
- Use this function to specify a set ID number.
- Refer to ‘Real Data Mapping 1’. See page 34.
1. Press the MENU button and then use the
DD
/
EE
button to select the SPECIAL menu.
2. Press the
GG
button and then use
DD
/
EE
button to select Set ID.
3. Press the
GG
button and then use F / G button to adjust Set ID to choose the desired
monitor ID number.
• The adjustment range of Set ID is 1 ~ 99.
4.
Repeatedly press the MENU button to return to normal viewing.
• Baud rate : 9600 bps (UART)
• Data length : 8 bits
• Parity : None
* Use a crossed (reverse) cable.
• Stop bit : 1 bit
• Communication code : ASCII code
Communication Parameters
Input
Language
Child lock
ISM Method
Low power
Set ID
Demo
OSD Rotate
Prev.
SPECIAL
Menu
Set ID
GG
1
T
ransmission
*
[Command 1] : First command to control PDP set.
(j, k, m or x)
*
[Command 2] : Second command to control PDP set.
*
[Set ID] : You can adjust the set ID to choose
desired monitor ID number in special
menu.
Adjustment range is 1 ~ 99.
When selecting Set ID ‘0’, every
connected PDP set is controlled.
Set ID is indicated as decimal (1~99) on
menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
*
[DATA] : To transmit command data.
Transmit ‘FF’ data to read status of
command.
*
[Cr] : Carriage Return
ASCII code ‘0x0D’
*
[ ] : ASCII code ‘space (0x20)’
[Command1][Command2][ ][Set ID][ ][Data][Cr]
OK Acknowledgement
* The set transmits ACK (acknowledgement) based on this
format when receiving normal data. At this time, if the data
is data read mode, it indicates present status data. If the
data is data write mode, it returns the data of the PC com-
puter.
[Command2][ ][Set ID][ ][OK][Data][x]
Error Acknowledgement
* The set transmits ACK (acknowledgement) based on this
format when receiving abnormal data from
non-viable functions or communication errors.
[Command2][ ][Set ID][ ][NG][Data][x]
Transmission / Receiving Protocol
Command Reference List
*
When setting the 22 ~ 29, a menu doesn’t display on screen.
Data 1: Illegal Code
2: not support function
3: Wait more time
01. Power k a 0 ~ 1
02. Input Select k b Refer to p. 31
03. Aspect Ratio k c Refer to p. 31
04. Screen Mute k d 0 ~ 1
05. Volume Mute k e 0 ~ 1
06. Volume Control k f 0 ~ 64
07. Contrast k g 0 ~ 64
08. Brightness k h 0 ~ 64
09. Colour k i 0 ~ 64
10. Tint k j 0 ~ 64
11. Sharpness k k 0 ~ 64
12. OSD Select k l 0 ~ 1
13.
Remote control lock mode
k m 0 ~ 1
14. Split Zoom k p 0 ~ 99
15. Treble k r 0 ~ 64
16. Bass k s 0 ~ 64
17. Balance k t 0 ~ 64
18.
Colour Temperature (CSM)
k u 0 ~ 3
19. Red Adjustment k v 0 ~ 50
20. Green Adjustment k w 0 ~ 50
21. Blue Adjustment k $ 0 ~ 50
22. Abnormal Status k z 0 ~ a
23. ISM Method j p 0 ~ 3
24. Low Power j q 0 ~ 1
25. Orbiter Time Setting j r 1 ~ FE
26. Orbiter Pixel Setting j s 1 ~ 3
27. Auto Configure j u 1
28. Send IR Code m c Key code
29. Input select x b Refer to p. 34