Does the product
cook correctly?
Check:
Inlet Gas Shut-o Valve is open.
Electrical power is connected and on.
Check for Display Status, if unit has a deluxe panel.
Security of MPO door.
All water connections are tight, inlet pressure is > 30 psi.
Incoming gas pressure is within specs.
Preliminary
Checks
Restart Oven:
( Control panel on )
Observe automatic call for heat if oven cavity was
cool.
Verify Convection Blower motor is up to speed.
Insure temp. quickly increases to set temp.
Yes
Does the unit heat up?
No
Baking Cavity
Checks.
No
Check probe for cleanliness , security,
and circuit for proper resistance value
changes per probe chart. (If unit uses a
deluxe panel, complete the calibration
check using the panel diagnostics
sequence.
Is it an Ignition box
problem?
Restart for heat while
checking MV output
Voltage.
Module Check:
Check for 24 VAC
input!
Check for 24 VAC
output from MV
terminal on module
during call for heat!
Display Check:
“Heat” should be
displayed on the
digital readout.
Temperature values
should display
while actual heat is
increasing.
Oven should reach set
temperature and cycle
burner o.
OK?
You
found
cause!
Call Garland Technical
Service
1-800-424-2411
Yes
Yes
No
No
Tell technical service
representative the checks
you made, and your
observations.
Select the lower scale of microamps on your multi-
meter.
Connect the red lead to the sense terminal on the
module, and the black lead to the sense wire that is
routed to the direct ignition ame sensor.
Recall for heat at the oven panel, while you watch the
ame current reading.
Flame current should be no less than 0.3 microamps
- steady
This modules will try for a stable burner ame 4 times,
and if not successful, will then lock out. A recall for heat
will them be required.
The following results should be determined:
- Did the ignitor produce a spark?
- During ignition, did the burners light?
- Did the burners remain on?
Yes
Moisture + Gas Heat Generation & Temperature Regulation System Troubleshooting guide