Part Number STH14 9/10 91
Carbonator Switch
(Switch in OFF position for
External Carb. and Juice
units, which turns off green
carbonator LED.)
• Switch supplies power to the
carbonator float switch and green
Carbonator LED only.
Green Carbonator LED
(Turned off on External
Carb. and Juice Units)
• The green carbonator LED
illuminates when carbonator
switch is in the ON position (only
applies to Internal Carb. units).
• The green carbonator LED will
flash rapidly when the carbonator
motor is running.
Carbonator Fill Timing
Jumper
(Not used on External Carb.
or Juice Units)
• Carbonator tank fill timing
provides pump failure protection
in the event of water loss to
carbonator pump (only applies to
Internal Carb. units).
• A jumper clip within the control
box sets the three optional time
settings. Units are shipped with
the jumper in (7) minute position
(only applies to Internal Carb.
units).
NOTE: Time tolerance is ±20%.
NOTE: See default mode functions
Green Compressor LED • Illuminates when the compressor
switch is in the ON position.
• Flashes once per second when
the compressor and condenser
fan are energized.
Element Function
J1 J1 J1
3 Minute 7 Minute Unlimited
STH14.book Page 91 Thursday, September 23, 2010 3:35 PM