CLEANING CHECKLIST
•Check CO
2
supply. If CO
2
supply is low, an arrow
on the primary regulator gauge will point to a
shaded area that reads “Low CO
2
” or “Change
CO
2
Cylinder.”
Check syrup supply.
Clean drain pan, grid, and splash panel.
Clean the valve nozzles and diffusers.
CEV WATER BATH
It is recommended that the water bath be drained at
least twice a year. Turn off the refrigeration.
Completely melt the ice bank. Refill the water bath
with fresh water until water runs out the overflow tube.
Turn on the refrigeration.
Disassembly
DISASSEMBLY FOR CLEANING AND
MAINTENANCE (ICE/BEVERAGE DISPENSERS)
NOTE: Sanitize the ice dispenser at Initial Start-up in
addition to monthly sanitizing. You will need a slotted
screwdriver in order to disassemble.
Disassemble parts in the following order:
A. Merchandiser
B. Ice chute
C. Paddle wheel or agitator pins
D. Agitator
E. Paddle wheel
F. Bin liner
G. Paddle wheel area