10 Technical data
10.1 Overview
External dimensions
SMS 55 SMS 55 Ex-
tra height
EURO 60 EURO 60
Extra
height
EURO 60
HP
Height (with slide
plate, if relevant)
[cm]:
75.9 82.4 75.9 82.4 86.4
Height (with ad-
justable plinth)
[cm]:
84.5–89.0 78.0–89.8 84.5–96.3 87.0–91.5
Width [cm]: 54.6 54.6 59.6 59.6 59.6
Depth [cm]: 57.2 57.2 57.2 57.2 57.2
Weight [kg]: 42 44 42 44 62
Ambient temperature
Minimum ambient temperature: +10°C
Plumbing
Cold or hot water up to 60°C: G¾"
Permitted pressure of water supply: 0.1–1.0MPa (1–10bar)
Max. pumping height: 1.2m
If the water pressure is too high, a pressure reducer valve must be fit-
ted.
Electrical connection
See identification plate
Safety concept
Provided power is going to the appliance, the electronic control unit monitors
the appliance. Any malfunction is indicated by error messages.
Overflow protection
In the event of a power failure, the overflow protection system is
rendered ineffective. Hence, the water tap should be turned off during
longer periods of non-use.