23
CAUTION
The spark plug must be tightened securely, or it may become very hot to damage the engine.
Only use recommended spark plug or the equivalent. Incorrect heat range of the spark plug
may damage the engine.
5. Spark Eliminator (Option) (Pic. 23)
The spark eliminator should be serviced at least once every
100 hours operation so as to keep it in a sound condition.
!
WARNING (Pic. 23)
The muffler is very hot during running the engine and even a long
Time after stopping. Never touch it, or you may get burns. Service
After the engine cools down.
a) Unscrew two nuts M4, and remove the exhaust elbow from the engine body.
b) Turn off five screws M5 from the muffler guard and take out the latter.
c) Turn off screw M4 from the spark eliminator and separate it from the muffler.
d) Clear away carbon deposit from the spark eliminator mesh with a brush.