21
4)Empty the oil in the air cleaner, Use non-flammable or high flash-point cleaning solvents to clean the dusty, and
then dry-up the air cleaner box.
5)install the air cleaner filter and cover to original position.
3.Washing of Deposit Cup.
Set the fuel switch at “OFF”, remove the deposit cup and O-ring. Wash them in non-flammable or high flash-point
cleansing solvents, and then dry them up, at last, carry out reinstallation. Set the fuel switch to “ON” and check for
leaks. (Pic. 19)
!
WARNING (Pic. 19)
Gasoline is extremely flammable and explosive in certain conditions.
Keep cigarette, sparks and open flames away.
After reinstalling the deposit cup, check it for leakage and make sure
the area around the engine is dry enough.
4. Spark Plug
Spark plug type: BP6ES, BPR6ES (NGK) or NHSPLD F6RTCU
(Pic. 20)