Parameter
Name
Factory preset
Min value
Max value
Signies
P2025 Extra drying time
Aut60°
30 (min) 10 45 Extra programme drying time after
exhaust temp. has been reached.
P2026 Cooling time
Aut60°
10 (min) 2 20 Time when only the fan is in
operation, without heating elements.
Provides more even drying time.