11
EVACUATION / AIR SUPPLY
When the cabinet is on, 45 m³ moist air per hour is evacuated. It must therefore be ensured that air can
enter the room to replace the moist air that is vented out.
CONNECTION TO EVACUATION
The drying cabinet is connected to an exhaust ventilation unit in accordance with standard.
The drying cabinet can be connected to the evacuation duct in two ways, either with a draft
stabilizer or permanently tted to a mechanical exhaust ventilation unit.
If the drying cabinet is to be connected to an existing ventilation system a draft stabilizer must always
be used, so that the general ventilation in the room is not aected.
Permanent tting must only be carried out when a separate exhaust-air duct is routed to the drying
cabinet, the air ow in the exhaust-air duct being adjusted to 45 m
3
per hour.
The drying cabinet has been tested and factory-set for connection with a draft stabilizer.