Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
range hood. See the “Venting Requirements” section.
2. Determine the location where the power supply cable will be
run through the wall. Be sure that the location will be covered
by the chimney of the range hood.
3. Drill a 1
1
/
4
" (3.2 cm) hole at this location.
4. Pull enough power supply cable through the wall to allow for
easy connection to the terminal box.
NOTE: Your range hood requires you to purchase either an
internal type or an in-line (external type) blower motor system.
For internal blower systems, there are blower motor mounting
parts in the blower motor installation packet that must be added
to the range hood prior to mounting the range hood to the wall.
See the “Install Range Hood Internal Blower Motor” section and
the instructions supplied with the blower motor.
Install Range Hood
1. Remove the grease lter. See “Range Hood Care” section.
2. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of range hood.
3. Level the range hood and tighten upper mounting screws.
4. Install 2 - 5 x 45 mm lower mounting screws and tighten.
Install Range Hood Internal Blower Motor
NOTE: Your range hood requires you to purchase either an
internal type or an in-line (external type) blower motor system.
See “Blower Motor System” in the “Accessories” section.
Prepare the Internal Blower System
IMPORTANT: Perform steps 1-4 before mounting the range
hood.
1. Remove grease lters from range hood. See the “Range
Hood Care” section in the Use and Care Guide.
2. Install the 6 mm nuts to the outside top or outside back
(alternate location on some models) of the range hood at the
proper location for the selected motor system.
Two 6 mm nuts are required for the single motor system.
Clip nuts into the small square notches located at the left
and right end of the square vent opening.
Five 6 mm nuts are required for the dual motor system.
Clip nuts into the small square notches, one located in
the front of the square vent opening and the other four
located at the left and right ends of the square vent
opening.
3. Mount range hood. See the “Install Range Hood” section.
Install Range Hood Internal Blower Motor
1. Install the range hood blower motor assembly inside the
range hood canopy with the wiring connection to the left for
the single motor system and to the front or top for the dual
motor system.
Single Blower Motor Assembly
A. Mounting screws
B. Mounting slots
A. Lower mounting screws
B
A
A
A
B
A. Wiring connection
A
A. Clip nut locations for dual motor assembly (5)
B. Clip nut locations for single motor assembly (2)
A. Lower mounting screws