Installation Dimensions
*NOTE: The range hood chimneys are adjustable and
designed to meet varying ceiling or soft heights depending
on the distance “X” between the bottom of the range hood
and the cooking surface. For higher ceilings, an Extension Kit
Part Number W10352733 is available from your dealer or an
authorized parts distributor. The chimney extension replaces the
upper chimney shipped with the range hood.
IMPORTANT:
Minimum distance “X”: 24" (61 cm) from electric cooking
surfaces
Minimum distance “X”: 30" (76.2 cm) from gas cooking
surfaces
The chimneys can be adjusted for ceilings between 8' 2
3
/
8
"
(2.5m) and 8' 10
5
/
16
" (2.7 m) when mounted at 30" (76.2 cm)
height over a gas cooking surface.
The chimneys can be adjusted for ceilings between 7' 8
3
/
8
"
(2.4m) and 8' 4
5
/
16
" (2.55 m) when mounted at 24" (61 cm)
height over electric cooking surface.
Venting Requirements
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efcient performance.
For the most efcient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If the roof or wall
cap has a damper, do not use the damper supplied with the
range hood.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold weather installations
An additional back draft damper should be installed to minimize
backward cold air ow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specied CFM of
air movement. The specied CFM varies from locale to locale.
Consult your HVAC professional for specic requirements in your
area.
Venting Methods
Typical Internal Blower Motor System Venting Installations
A 10" (25.4 cm) round vent system is needed for installation (not
included). The range hood exhaust opening is 10" (25.4 cm)
round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall. To
vent through the wall, a 90º elbow is needed.
X*
18" (45.7 cm) mini
mum
c
learance upper
cabinet to counter
top
36" (91.4 cm)
See Note
*
countertop height
36" (91.4 cm) or 48" (121.9 cm)
or cabinet opening width
(if installed between cabinets)
Roof venting Wall venting
A
A
B
B
A. Roof cap
B. 10" (25.4 cm)
round vent
A. Wall cap
B. 10" (25.4 cm)
round vent