Periodically, check the following:
Examine the optical sensors, ensuring they are clear of dirt and dust. If necessary, clean the front surface with a soft towel. Never use solvents,
cleaners or mechanically abrasive towels to clean the Light Curtains because this can damage the optical sensors. Avoid direct, high-pressure water
spray to clean the Light Curtains. Do not scratch the surface of the optical sensors when cleaning the Light Curtains.
Check the mounting brackets, make sure they are securely fastened to the mounting surfaces. Tighten if necessary.
Check that the Light Curtain cables are secured properly.
AMBER LED GREEN LED STATUS SOLUTION
OFF OFF No power Check wiring.
ON Blinks • Light Curtain receiver and transmitter are not aligned Adjust the Light Curtains to correct alignment
Obstructed light beam • Remove the obstruction
Defective Light Curtain Receiver Replace Light Curtain receiver and transmitter
(Model LC-36A)
TEST THE PRIMARY AND ANCILLARY ENTRAPMENT PROTECTION
It is the responsibility of the specifier, purchaser, and installer to ensure that, on completion, the installation of the Light Curtain complies with all
relevant federal, state, and local codes and regulations.
TEST THE LIGHT CURTAIN (ANCILLARY ENTRAPMENT PROTECTION)
1. With the door in the full open position, press the close button.
2. While the door is closing, obstruct any of the invisible light beams on the Light Curtain (the green LED on the Light Curtain Receiver will blink when
the invisible light beam is obstructed). The door should stop and reverse.
TEST THE PHOTOELECTRIC SENSORS (PRIMARY ENTRAPMENT PROTECTION)
1. With the door in the full open position place an obstruction in the path of the photoelectric sensors and press the close button. The operator should
not move.
2. Remove the obstruction and press the close button. The door should close.
ALIGN THE LIGHT CURTAINS
The Light Curtain transmitter and receiver must be aligned. When properly wired and aligned the amber and green LEDs will be ON. The amber LED is
located on the Light Curtain Transmitter and the green LED is located on the Light Curtain Receiver. If the amber and green LEDs are not on, refer to
the table below.
1. Open and close the door for one complete cycle to let the operator register the Light Curtain.
FINISH INSTALLATION
MAINTENANCE
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this digital device are prohibited. THERE ARE NO OTHER USER SERVICEABLE PARTS. Any
changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC rules and IC License-Exempt RSS Standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Loading ...
Loading ...
Loading ...