Loading ...
Loading ...
3
CARTON INVENTORY
SPECIFICATIONS
Optical
Operating range: ............................................3 - 33 feet (.91 - 10 meters)
Coverage area: ............................................. 36" (91.4 cm) detection zone
Number of optical sensors: ......................................................................8
Number of invisible light beams: ............................................................22
Receiver LED: ................................................................................... Green
Transmitter LED: ............................................................................. Amber
Electrical
Current Draw ................................................................................... 40 mA
Supply voltage: .....................................................18 to 30 volts AC or DC
Output Type: ......Solid-state Relay, Normally Open (N.O.) when energized
Mechanical
Housing material: ...................................................... Aluminum, anodized
Cable length: ...............................................................................6'6" (2m)
Enclosure rating: ...........................................................................NEMA 4
Operating temperature range: .............- 40°F to +140°F (- 40°C to +60°C)
Storage temperature range: ............... - 40°F to +185°F (- 40°C to +85°C)
Dimensions
Light Curtain Receiver
Mounting Brackets (4)
Light Curtain Transmitter
Red cable end
Green LED
Black cable end
Amber LED
Optical Sensors (8)
2' 9.5"
(86.1 cm)
.2" (5 mm)
.27" (7 mm)
LED
3' 8.25"
(112 cm)
1' 6.23"
(46.3 cm)
.47" (12 mm)
44" (111.8 cm) length with 36" (91.4 cm) detection zone
APPLICATION
The Light Curtain is compatible with LiftMaster Heavy, Standard, and
Medium Duty Logic, FDC, FDCL, FDOA, FDOB, and Egress Commercial
Door Operators. The Light Curtain is approved for track mounting. The
Light Curtain is for indoor use only but may be installed in areas exposed
to rain or moisture.
INTRODUCTION
The images in this document are for reference only and your product may look different.
ACCESSORIES
Conduit Kit ...............................................................................OES-COND
Conduit kit with 2 junction boxes and 2 fl exible cables.
Plug-In Power Supply ...............................................................100MAPS
For medium-duty LiftMaster commercial door operators with low current
capability. Also for use with Logic operators for additional power to
operate the Light Curtains.
Not Shown
Screws, Washers, and Nuts with Nylon Insert
Wire Connectors (6)
• Blocking Material
• Installation Manual