L FToUP COOKTOP
The cooktop lilts up so the cooktop and area underneath
(burner box) can be cleaned, Before lifting the cooktop:
1. Remove burner grates, drip bowl liners, and knobs.
To lift the cooktop, grasp at the front through burner
bowls and lift up; lift the support rod to hold the cooktop
up while cleaning.
When finished, carefully lower the support rod and
cooktop, press the cooktop into place° Make sure the
strtkes fit in the catches to fasten the cooktop into place.
Replace drip bowl liners and burner grates.
REMOVABLE COOKTOP
The cooktop burners on your range may be removed for
cleaning, Be sure all cooktop knobs are turned to OFF
and burners are cool, then raise the cooktopo
if shipping screws were not removed from the burner
when the range was installed, do so now (see your
installation section for instructions).
TO rel_'tOVe bua'nevs:
Place fingers from left hand (left side), right hand
(right side), under flash tube bracket.
Lift with an upward and outward motion to the left (for
the left burners) and to the right (for the right burn_
ers).
. Ease off the valve orifice hood. (See Ftg_A).
Check lighter and burner ports (Fig. B). if they are
clogged, use a small sewing needle orpin to clear them.
See the Cleaning Chart°
Be careful not to disturb the air shutter setting while
cleaning, tf you need to readjust the air shutter, see the
installation instruction packed with your counter unit.
3"0 repllace burners:
Place venturi on valve orifice hood.
Relnsert flash tube bracket tabs into slots on burner
support°
Make sure flash tube bracket is supported by burner
support and burnerhead isresting on burner bracket.
(See Fig. B).
\
BURNER SUPPORT
FLASH TUBE BRACKET
VALVE ORIFICE HOOD
Fig, A
VALVE ORIFICE HOOD
VENTURI
BURNER
_SUPPORT
SLOTS
BURNER
BRACKET
Flg, B
7 NGMNT26