Malfunction description Causes Solution
Any indicator lamp off and
no heating.
Rice cooker not plugged.
Verify the main plug is well
engaged in the product
body.
Any indicator lamp off and
heating.
Problem of the connection
of the indicator lamp or
indicator lamp is damaged.
Send to the authorized
service center for repair.
Steam leakage during
using.
Lid is badly closed.
Open and close again the
lid.
Micro pressure valve not
well positioned or
uncomplete.
Stop the cooking (unplug
the product) and check the
valve is complete (2 parts
locked together) and well
positioned.
Lid or micro pressure valve
gasket is damaged.
Send to the authorized
service center for repair.
Rice half cooked or
overtime cooking.
Too much or not enough
water compared to rice
quantity.
Refer to table for water
quantity.
Rice half cooked or
overtime cooking.
Not sufficiently simmered.
Simmer as required in table
cooking paragraph.
Automatic warm-keeping
fails (product stay in
cooking position,
or no heating).
Send to authorized service
center for repair.
Error Code E2 on the
display.
Rice Cooker starts a cooking
mode without inner pot
inside.
Unplug the product during
10 seconds and then plug
again.
Remark: if inner bowl is deformed, do not use it anymore and get a replacement from the
authorized service center for repair.