Ivation IVALDH70PW Dehumidifier

User Manual - Page 8

For IVALDH70PW.

PDF File Manual, 10 pages, Read Online | Download pdf file

IVALDH70PW photo
Loading ...
Loading ...
Loading ...
Removing Collected Water
There are two ways to remove collected water.
1. Using the reservoir
When the unit is Off, if the reservoir is full, the unit will beep eight (8)
times, the Full indicator light will flash, and the digital display will
show P2.
When the unit is On, if the reservoir is full, the compressor turns off and
the fan turns off after 30 seconds to dry the water in the condenser.
Then the unit will beep eight (8) times, the Full indicator light will flash,
the digital display shows P2.
Slowly remove the reservoir. Grip the left and right handles securely,
and carefully slide out straight so water does not spill. Do not rest it
on the floor because the bottom of the reservoir is uneven. It will
fall and cause the water to spill.
Discard water and replace the reservoir. The reservoir must be in
place securely for the dehumidifier to operate.
The machine will re-start when the reservoir is restored in its correct position.
NOTES:
When you remove the reservoir, do not touch any parts inside of the unit. Doing so may
damage the product.
Be sure to slide the reservoir gently all the way into the unit. Banging the reservoir against
anything or failing to secure it may cause the unit not to operate.
When the reservoir is removed, if water remains in the unit, it must be dried.
2. Continuous draining
Water can be automatically emptied into a floor drain by attaching the
unit with a water hose (Id≥ 5/16, not included) with a female threaded
end (ID:M=1, not included).
Install the drain hose onto the adaptor (See illustration).
Remove the plastic cover from the back drain outlet of the unit and set
aside, remove reservoir, then insert the drain hose through the drain
outlet of the unit and securely press it into the connector on the front
of the unit. (See illustration)
Tighten the adaptor and the unit by using two screws
(placed in the reservoir).
Install the female threaded end of the water hose into the
adaptor (See illustration), then lead the water hose to the
floor drain or a suitable drainage facility.
Make sure the hose is secure so there are no leaks.
Direct the hose toward drain, making sure that there are
no kinks to stop water flow.
Place the end of the hose into the drain and make sure the
end of the hose is level or positioned in a downward direction to
let the water flow smoothly. Do not raise the hose above the floor.
Place the reservoir back in the unit and make sure that it is
correctly secured.
Select the desired humidity setting and fan speed on the unit for
continuous draining to start.
NOTE: When the continuous drain feature is not being used, remove the drain hose from outlet.
Drain hose
Adaptor
Plastic cover
Connector
Drain hose
Water hose
Female thread
end
8
Loading ...
Loading ...