Ivation IVALDH70PW Dehumidifier

User Manual - Page 5

For IVALDH70PW.

PDF File Manual, 10 pages, Read Online | Download pdf file

IVALDH70PW photo
Loading ...
Loading ...
Loading ...
Error Codes and Protection Code:
AS Humidity sensor error: Unplug the unit and plug it in again. If error repeats, call for service.
ES Temperature sensor error: Unplug the unit and plug it in again. If error repeats, call
for service.
P2 Reservoir is full or reservoir is not in right position: Empty the reservoir and replace it in
the right position.
Additional Features
Full Light: Glows when the reservoir is ready to be emptied, when the reservoir has been
removed or has not been replaced in the proper position.
Auto Shut Off: The dehumidifier shuts off automatically after 30 seconds when the reservoir
is full, or when the reservoir is removed or not replaced in the proper position. When the set
humidity level is reached, the unit will also shut off automatically. For some models, the fan
motor will continue operating.
Auto Defrost: When frost builds up on the evaporator coils, the compressor will cycle off and
the fan will continue to run until the frost disappears.
Three (3) Minute Restart Delay: After the unit has stopped, it cannot restart within the first
three (3 ) minutes. Operation will automatically start again after three (3) minutes.
Check Filter Feature: The system starts to count down the time once the fan motor operates.
The Check Filter feature can only be activated when the total operation time reaches 250 hours
or more. The Reset Light (Clean Filter indicator) flashes once per second if the filter requires
cleaning. Press the Filter button and the Reset light (Clean Filter indicator light) will turn off.
Auto-Restart: If the unit shuts off unexpectedly due to a power outage, it will restart with
the previous function setting automatically when the power resumes.
Setting the Timer
When the power is on, press the Timer button. The Timer Off indicator light will illuminate.
This indicates that the Auto Stop function is initiated. Press it again and the Timer On
indicator light will illuminate. This indicates that Auto Start is initiated.
When the power is off, press the Timer button. The Timer On indicator light will illuminate.
This indicates that the Auto Start function is initiated. Press it again and the Timer Off
indicator light will illuminate. This indicates that Auto Stop is initiated.
Press or hold the UP or DOWN buttons to change the Auto time by 0.5 hour increments
up to ten (10) hours, and at one (1) hour increments up to 24 hours. The control will count
down the remaining time until start.
The selected time will register in five (5) seconds and the system will automatically revert
to display the previous humidity setting.
When the Auto Start and Auto Stop times are set within the same program sequence, the
Timer On/Off indicator lights illuminate together identifying both On and Off times are
now programmed.
Turning the unit On or Off at any time or adjusting the timer setting to 0.0 will cancel the
Auto Start/Stop function.
When LED display window displays the code P2, the Auto Start/Stop function will also
be canceled.