Faber DAMIS36SS Dama Isola Halogen

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Specification Other Documents

User Manual

This is the main product document for model DAMIS36SS.

The file format is pdf, 24 pages, you can download this manual here .

background
Dama Isola (Electronic Controls)
Island Mount Canopy Rangehood


Version 01/12 - Page 1
READ AND SAVE THESE INSTRUCTIONS



 



 
 
 



  
  
 

 
 
 




 
 





 




 



 

 












background
VENTING REQUIREMENTS
Determine which venting method is best for your application.
Ductwork can extend either through the wall or the roof.
The length of the ductwork and the number of elbows should

size of the ductwork should be uniform. Do not install two


around the cap.
Flexible ductwork is not recommended. If it is used,
each foot of exible ductwork used is equivalent to
two feet of straight metal ductwork when calculating
the ductrun length. Thus, a exible elbow equals two
standard elbows.



cut, then a supporting frame must be constructed.

TO PAGE 4.
WARNING - To Reduce The Risk Of Fire, Use Only Metal
Ductwork.
ELECTRICAL REQUIREMENTS

separate 15 amp fused circuit. A time-delay fuse or circuit
breaker is recommended. The fuse must be sized per local
codes in accordance with the electrical rating of this unit as
        
  
      
must conform to the requirements of the National Electrical

ordinances. Wire size and connections must conform with the

may be obtained from:
National Fire Protection Association

Quincy, Massachusetts 02269

DO NOT terminate the ductwork in an attic or other
enclosed space.
DO NOT use 4" laundry-type wall caps.

DO NOT
ventilation air.


This appliance should be connected directly to the fused

nonmetallic sheathed copper cable. Allow some slack in the
cable so the appliance can be moved if servicing is ever nec-

at each end of the power supply cable (at the appliance and

When making the electrical connection, cut a 1 1/4" hole
in the wall. A hole cut through wood must be sanded until
smooth. A hole through metal must have a grommet.
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, do not use this fan with any solid-state speed
control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING: Use this unit only in the manner intended
by the manufacturer. If you have any questions, contact
the manufacturer.
Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
Whenthe servicedisconnecting meanscannotbelocked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
CAUTION: For General Ventilating Use Only. Do Not
Use To Exhaust Hazardous or Explosive Materials and
Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:InstallationWorkAndElectricalWiringMust
Be Done By Qualied Person(s) In Accordance With All
Applicable Codes And Standards, Including Fire-Rated
Construction.
Sufcient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
ProtectionAssociation (NFPA), andtheAmerican Society
forHeating,RefrigerationandAirConditioningEngineers
(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not dam-
age electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
WARNING


nonmetallic gaskets or other materials, DO NOT
use for grounding.


circuit. A fuse in the neutral or grounding circuit
could result in electrical shock.

as to whether the rangehood is properly grounded.


WARNING
For residential use only.
!
!
Cold Weather installations
An additional back draft damper should be installed to minimize

be installed to minimize conduction of outside temperatures
as part of the vent system. The damper should be on the cold
air side of the thermal break. The break should be as close as
possible to where the vent system enters the heated portion
of the house.
CAUTION: To reduce risk of re and to properly exhaust air, be
sure to duct air outside - do not vent exhuast air into spaces within
walls or ceilings or into attics, crawl spaces or garages.
background
RÈGLEMENTS D'ÉVACUATION

le toit.


  

métallique à l'intérieur et scellez bien le clapet extérieur avec
du calfeutrage.
Utilisez un tuyau d'évacuation rigide lorsque possible.
Un tuyau exible égale deux fois plus qu'un tuyau rigide,
ce qui réduit la puissance d'évacuation.
Veillez à ce que l'espace pour le tuyau soit ample - ainsi on
n'aurait pas besoin de découper les supports de mur intérieur.
Si ce découpage est nécessaire, veillez bien à ce qu'un
renforcement soit mis en place.
RÈGLEMENTS DVACUATION ADDITIONELL - PAGE 11.
AVERTISSEMENT - Pour Ne Pas Risquer Un Feu, Utilisez
Seulement Les Matériaux Métalliques.
qu'un contact d'un demi-pouce (1/2 po.) soit installé à chaque

Faites un trou de 1 1/4 po. dans le mur. S'il s'agit d'un trou en
bois - sablez-le bien, tandis qu'un trou passant par le métal
demande un bouche-trou.
AVERTISSEMENT - POUR RÉDUIRE LE RISQUE
D'INCENDIE OU DE CHOC ELECTRIQUE, ne pas utiliser
ce ventilateur en conjonction avec un dispositif de réglage
de vitesse à semi-conducteurs.
AVERTISSEMENT POUR MINIMISER LES RISQUES
D’INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, OBSERVER LES PRESCRIPTIONS
SUIVANTES: Suivez les recommandations du fabricant
et entre en communication avec lui pour toute
information.
Fermez le courant avant tout entretien et veillez a ce qu'il
reste fermé. Si on ne peut pas verrouiller le panneaux
du service électrique, afchez un avis de danger sur la
porte.
AVIS: Pour L'évacuation Générale - Veillez à Ne Pas
Evacuer Des Matériaux Ou Vapeurs Explosif.
AVERTISSEMENT POUR MINIMISER LES RISQUES
D’INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES
CORPORELS, OBSERVER LES PRESCRIPTIONS
SUIVANTES: L'installation Et Le Raccordement Electrique
Doivent Se Faire Par Un Technicien Qualié Selon Tous
Les Codes Municipaux.
An d'obtenir un rendement maximal en ce qui a trait à la
combustion ainsi qu'à l'évacuation des gaz par la conduite
de cheminée, une bonne aération est nécessaire pour
tous les appareils à combustion. Suivez les conseils et
mesures de sécurité du fournisseur tels que ceux publiés
par l'Association Nationale de la Sauvegarde contre
l'Incendie et l'Association Américaine d'Ingénieurs de
Chauffage, Frigorifaction et Air Climatisé ainsi que les
codes municipaux.
En perçant un mur veillez à ne pas perforer un autre l
électrique.
Une ventilateur à évacuation extérieure doit être
raccordée à l'extérieur.
AVERTISSEMENT


mansarde soit dans un espace enfermé.




occasionner un feu.
FICHE TECHNIQUE ÉLECTRIQUE
Le raccordement électrique doit se faire avec un circuit séparé
de 15 ampères fusible à 120V, 60 Hz, courant alternant. On
recommande un coupe-circuit. La taille du fusible doit se
      
        
devra aussi se conformer aux règlements du code national

    
informations chez:
l'Association Nationale de la Prévention du Feu

Quincy, Massachusetts 02269






métallique ou autre.


mise à terre - ce qui peut causer une secousse
électrique.

soit bien mise à terre.

occasionner un feu.
AVERTISSEMENT
Uniquement pour usage menager.
!
!
Installations pour régions à climat froid


thermique pour minimiser la conduction de chaleur par l'intermédiaire
du conduit d'évacuation, de l'intérieur de la maison à l'extérieur. Le


possible de l'endroit le système d'évacuation s'introduit dans la
partie chauffée de la maison.
background
TOOLS NEEDED FOR INSTALLATION













PARTS SUPPLIED FOR INSTALLATION


PARTS NEEDED FOR INSTALLATION




OPTIONAL ACCESSORIES AVAILABLE
High Ceiling Chimney Kit
Extends the island chimney for high
ceilings
part # HIGH2 - Stainless
*Ductless Conversion Kit
For non-vented installations only
* it is highly recommended that professional
style cooking always be vented to the
outside

Replacement Charcoal Filter
For non-vented installations only,

part # FILTER2
UNPACK THE RANGEHOOD


THIS TIME! This plastic covering protects the chimney from scratches during installation.
For safe packaging, the entire chimney section of the hood is shipped assembled. It must be disassembled completely for
installation. Disassemble packaged chimney components by sliding apart the chimney covers (B and C in FIGURE 1). Remove
(B) (F) by removing the 2 philips screws on the outside bottom
(C) (F) by removing the 2 philips
screws on the outside top of the chimney cover.
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 35 equivalent
feet if ducted with the required minimum of 6"

by adding the equivalent feet in FIGURE 2 for
each piece of duct in the system. An example
is given in FIGURE 3.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum
of 24" of straight duct between elbows if
more than one is used. Do not install two
elbows together. If you must elbow right
away, do it as far away from the hood's
exhaust opening as possible.
9 Feet Straight Duct


Total System
FIGURE 3
3.0 feet
5.0 feet
12.0 feet
0.0 feet




FIGURE 2
9.0 feet
10.0 feet
0.0 feet
19.0 feet
PREPARING TO ATTACH THE CHIMNEY
The rangehood attaches to the ceiling by a
metal support structure (D in FIGURE 1). This
support must be attached to the ceiling before
the canopy is attached. This structure must

FOR WOOD CEILINGS:    
wood screws and washers.
FOR PLASTER OR SHEET ROCK CEILINGS:
If possible, the support must be attached to

behind the sheet rock must be built.
FOR WOOD SHELVES: G, H, &
I in FIGURE 1.
FIGURE 1

A. 
B. 
C. 
D. 
E. 
F. 
G. 
H. WOOD SHELF WASHERS
I. 
J. 
K. 
L. 
M. DAMPER
J
K
L
M
background
upper
chimney
cover
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
8 3/8” min
15 3/8” max
23
5/8”
4 3/4”
36”
FIGURE 4
DUCTED
DIMENSIONS
x
min & max ceiling height examples
x = 30"
min
8'
6 3/4"
max
9'
1 3/4"
x = 28"
min
8'
4 3/4"
max
8'
11 3/4"
x = 26"
min
8'
2 3/4"
max
8'
9 3/4"
x = 24"
min
8'
3/4"
max
8'


and designed to meet varying ceiling heights
as indicated in FIGURE 4. The chimney can

9' 1 3/4" depending on the distance between
the bottom of the hood and the cooktop
(distance x in FIGURE 4).
For higher ceiling installations, the High
Ceiling Chimney Kit includes an additional
support structure which adds 21" to the
ceiling heights in FIGURE 4.
NOTE: The chimney structure can reduce
down to a 27" minimum height. To reduce
the height, the middle section of the
support structure (FIGURE 5) needs to
be removed. Out of the box, the minimum
chimney length is 32". Subtract 5" from
all minimum ceiling height calculations in
FIGURE 4 if removing the middle
section.
DUCTED INSTALLATION DIMENSIONS
(vented to the outside)
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. When installed ductless, the rangehood vents out of grates on either
side of the lower chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer.
WARNING!

WARNING

AND WEIGHT OF THIS
RANGEHOOD, THE

  

or sheet rock ceilings, the
support must be attached
 
possible, a support structure
must be built behind the
plaster or sheet rock. The
manufacturer assumes no
   
damage caused by improper
installations.
!
11 7/16"
FIGURE 5
26
40 1/16"
background
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. When installed ductless, the rangehood vents out of grates on
either side of the lower chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer.
WARNING!

The ductless Dama Isola chimney is
     
indicated in FIGURE 6. The chimney can be

1 3/4" depending on the distance between
the bottom of the hood and the cooktop
(distance x in FIGURE 6).
For higher ceiling installations, the High
Ceiling Chimney Kit includes an additional
support structure which adds 21" to the
various ceiling heights in FIGURE 6.
upper
chimney
cover
ductless
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
8 3/8” min
15 3/8” max
23
5/8”
36”
FIGURE 6
DUCTLESS
DIMENSIONS
x
min & max ceiling height examples
x = 30"
min
8'
6 3/4"
max
9'
1 3/4"
x = 28"
min
8'
4 3/4"
max
8'
11 3/4"
x = 26"
min
8'
2 3/4"
max
8'
9 3/4"
x = 24"
min
8'
3/4"
max
8'

DUCTLESS INSTALLATION DIMENSIONS
(not vented to the outside)
12 1/2"
4 3/4”
3 1/2”
WARNING

AND WEIGHT OF THIS
RANGEHOOD, THE



or sheet rock ceilings, the
support must be attached
     
not possible, a support
structure must be built
behind the plaster or sheet
rock. The manufacturer
assumes no responsibility

by improper installations.
!
11 7/16"
40 1/16"
background
.
ATTACH THE SUPPORT
4. Determine and make necessary cuts for the ductwork. The duct
opening is shown on the mounting template (L in FIGURE 7). Install
ductwork before mounting the support.
FIGURE 7
1. Put a thick, protective
covering over cooktop,
set-in range or countertop
to protect from damage
or dirt.
2. Determine and clearly
mark with a pencil on the
ceiling where the rangehood
will be installed.
3. A template (L in FIGURE
7) for mounting the support
is supplied in the carton

template to mark holes for
support on the ceiling.
8. Install in previously drilled pilot holes in the ceiling the 4 bolts,
washers and nuts OR the wood screws from the parts bag depending
on your ceiling type (PAGE 4).
(A IN FIGURE 9).
9. Remove wiring box cover located on the top section of the chimney
support.
10. 
screws can be tightened after the chimney support is
attached to the ceiling.
11. 
through the strain relief.
12. Position the chimney support so that the large end of the
keyhole slots are over the ceiling attachment bolts (B IN FIGURE 9).
Then push the chimney support so that the bolts are in the neck of
the slots. (C IN FIGURE 9) Tighten bolts securely.
IMPORTANT: The chimney support must be securely
attached to the ceiling.
13. 
the length of the support by removing the four screws (indicated
in FIGURE 10)
support is determined, install and tighten the four screws.
6. 

DO
NOT turn on the power until installation is complete! A knockout

7. For ducted installations, place the round DAMPER (N in FIGURE
1) into the exhaust opening of the rangehood and press down.
5. If using the High Ceiling Chimney Kit
(A in FIGURE 8). Position
(B in
FIGURE 8) so that the outside edges and the electrical holes line up.

the 4 bolts (C in FIGURE 8). Tighten bolts securely.
FIGURE 10
FIGURE 8
FIGURE 9
A. 1/4"
B
C
background
14. REMOVING THE MIDDLE TRESTLE COMPONENT
NOTE: The chimney structure can reduce down to a 27 " minimum height. To reduce the height,
the middle section of the support structure needs to be removed.
Out of the box, the minimum chimney length is 32 ".
Insure the the installation process outlined in the U&C is followed and there is sufficient stability with the
middle section removed.
background
FIGURE 13
MAKE THE ELECTRICAL CONNECTION
        (SEE
FIGURE 11) DO NOT turn on the power until installation is
complete! 

Green grounding screw. Attach the White lead of the power
supply to the White lead of the rangehood with a twist-on type
         

connector.
1.   
 (C in FIGURE 13)
attaches to the top of the
support structure using two
screws provided (G in FIGURE
13). If using the High Ceiling
Chimney Kit
  
with the kit. Slide up and


2. Attach the duct work to the
DAMPER (M in FIGURE 1).

duct tape to prevent leaks.
3.   
 (B in FIGURE 13)
attaches using two screws
provided (G in FIGURE 13).


  


(B in FIGURE 12) with the holes
(D in FIGURE 12) and snap
in the VENT GRIDS (C in FIGURE 12).
INSTALLING THE RANGEHOOD
A. Home power supply cable
 
 
D.White wires
E. Green (or bare) ground wire from home power supply
connected to green ground screw
F. Range hood power supply cable
G.Range hood power supply cable connected to green
ground screw
FIGURE 11
Ductless installations require
a Ductless Conversion
Kit whose components are
pictured in FIGURE 12. Do
not use the DAMPER (M
in FIGURE 1) for ductless
installations. The LOWER
  (B
in FIGURE 1) should be
discarded and replaced by
the new one with holes from
the Ductless Conversion Kit
(D in FIGURE 12).
As indicated in FIGURE
12   
DIVERTER (A) over the

(E)
 
 (B) into the
DIVERTER (A).
FIGURE 12
FOR DUCTLESS INSTALLATIONS
background
(F in
FIGURE 12) 
and locking into place. See FIGURE 16
WARNING

Two people must hold the canopy in place while the third person installs the screws that attach the canopy to the chimney.

4. (A in FIGURE
12) to the assembled chimney support using the four bolts
provided (F in FIGURE 14).
FIGURE 14
FIGURE 16
6. (FIGURE 17).
FIGURE 17
7. Turn the power supply on. Turn on blower and lights. If the
rangehood does not operate, check that the circuit breaker is
not tripped or the house fuse blown. If the unit still does not
operate, disconnect the power supply and check that the wiring
connections have been made properly.
5. 
A in FIGURE 15
indicated in B in FIGURE 15
(A in FIGURE 15) 
(C in FIGURE 15) by connecting the two black plastic


the METAL FLANGE (D in FIGURE 15).
FIGURE 15
MAKE THE INTERNAL ELECTRICAL CONNECTIONS
C
A
B
D
A
B
!
background
FIGURE 18
FIGURE 19
USE AND CARE INFORMATION
This rangehood system is designed to remove smoke, cooking
vapors and odors from the cooktop area.
Rangehood Control Panel
The control panel is located under the front edge of the rangehood
canopy. The position and function of each control button are
indicated in FIGURE 18.
For Best Results
Start the rangehood several minutes before cooking to develop

after cooking is complete to clear all smoke and odors from
the kitchen.
Cleaning

hot detergent solution or washed in the dishwasher. Stainless
steel cleaner should be used on stainless rangehoods. Abrasives


Replacing the Lamps
       
light switch is turned off. Remove the 2 screws (as indicated
in FIGURE 19) that hold the light support and gently pull the
support down from the hood. Remove the lamp from the light
support and replace with new lamp. Replace the light support

An alternative method to replace the lamps is to use a 1 1/4"
suction cup (FIGURE 20). Attach the suction cup to the bulb


FIGURE 20
WIRING DIAGRAM
0 1 2 3 4 5 6 7 8 9
Creato da.
Rev :
Ver :
DOLCE CORRADO
Materiali: non deveno contenere Pb, Cr6+, Hg, PBB, pbde, ai sensi della direttiva 2002/95 CE
SCHEMA ELETTRICO M8-4V ESB FARETTI
Non rilevare quote dal grafico non ap portare modifiche senza l'autorizzazione d'ufficio progettazione
a termini di legge ci riserviamo la prop rieta' del presente disegno con divieto di riproduzione totale o parziale
Code :
Disegno N :
Data:
08.Set.2010
LINE IN
120Vac
60Hz ~
L
N
Y-G
WIRING BOX
BLU
RED
BLK
WHT
Y-G
1
2
3
4
5
6
BLK
V1
MC
F
V2
ESB
0
MOTOR
1
MOTOR
BRW
GRY
BLU
123
6 5 4
789
1 2 3
654
987
RED
M8 4V
120V ~
WHT
BRW
2
SPEED
BLU
BLK
1
1
BLK
BLK
WHT
2
2
WHT
ORG
BRW
3
3
BRW
GRY
4
4
GRY
RED
WHT
BLU
Y-G
BLU
5
5
BLU
3/I
SPEED
RED
6
6
RED
WHT
7
7
WHT
VLT(ORG)
8
8
VLT(ORG)
RED(ORG)
9
9
RED(ORG)
RED
10
10
RED
VLT
11
11
VLT
0-1
LIGHT
12
12
TOROIDAL
TRANSFORMER
WHT
4
3
BLK
RED
2
1
BLK
N
L
V4
L
V3
ORG
2
1
RED
ORG
4
3
VLT
WHT
1
2
3
4
5
6
ORG
WHT
BRW
GRY
ORG
RED(ORG)
VLT(ORG)
RED
VLT
PRI.
SEC.
ELECTRONIC
TRNSFORMER
VLT
RED
HALOGEN
LAMPS
VLT
INCANDESCENT
LAMP
RED
HALOGEN
LAMPS
HALOGEN
LAMPS
HALOGEN
LAMPS
L
V
M
Light On/Off Button ( L )
On/Off switch for the halogen lights. Press the light button to
turn the light ON. and again to turn off.
Blower Off Button ( M )
Off switch for the blower. The blower can be operated by pressing
any of the speed buttons
Blower Speed Button ( V )
Speed control for blower. Press the switch "1" for LOW speed,

speed 3 button for 5 seconds to activate the intensive speed.
Which operates the hood for 10 minutes on the high speed and
then returns the previous speed.
background
FABER WARRANTY & SERVICE (SAVE FOR YOUR RECORDS)
All Faber products are warranteed against any defect in materials or workmanship for the
original purchaser for a period of 1 year from the date of original purchase. This warranty
covers labor and replacement parts. To obtain warranty service, contact the dealer from
whom you purchased the rangehood, or the local Faber distributor. If you cannot identify
a local Faber distributor, contact us at (508) 358-5353 for the name of a distributor in your
area.
The Following is not covered by Faber's warranty:
1. Service calls to correct the installation of your range hood, to instruct you how to use your
range hood, to replace or repair house fuses or to correct house wiring or plumbing.
 
consumable parts are excluded from warranty coverage.
3. Repairs when your range hood is used for other than normal, single-family
household use.
 
improper installation, installation not in accordance with electrical or plumbing codes, or
use of products not approved by Faber.
 

 
rangehood.
 
and delivery charges. Faber range hoods should be serviced in the home.
Record Your Information Below:
Serial #: __________________________
Date of Purchase: ______________
background
OUTILS NÉCESSAIRES À L’INSTALLATION













PIÈCES FOURNIES POUR L’INSTALLATION


PIÈCES NÉCESSAIRES POUR L’INSTALLATION




ACCESSOIRES POUR L’INSTALLATION
Haut kit de cheminée de plafond
Prolonge la cheminée d'île pour les plafonds
hauts
part # HIGH2 - Stainless
*Kit Pour Conversion Du Conduit
Pour installation sans conduit
* Il est fortement recommandé que toute ventilation
     


Filtres au Charbon
Pour installation sans conduit
part # FILTER2
DÉBALLER LA HOTTE



(C de la FIGURE 1)(B de la
FIGURE 1) du TREILIS (F de la FIGURE 1) en dévissant les quatre vis.
CALCUL DE LONGUEUR DU CONDUIT



en pied de la FIGURE 2 pour chaque pièce du

à la FIGURE 3.
Pour de meilleurs résultats, ne pas utiliser
plus de trois coudes de 90
o
. S’assurer qu’il
y ait un minimum de 24 po de conduit
droit entre les coudes si l’on utilise plus
d’un coude. Ne pas installer deux coudes
ensemble.
9 pi de conduit droit


Système total
FIGURE 3
3,0 pi
5,0 pi
12,0 pi
0,0 pi




FIGURE 2
9,0 pi
10,0 pi
0,0 pi
19,0 pi
INSTALLATION DU SUPPORT
        
support métallique (D de la FIGURE 1)

la hotte ne soit installée au support. Puisque
cette structure supporte le poids de la hotte,
      

quatre longues vis à bois 4 po. et rondelles.



     

G, H, & I de
la FIGURE 1.
FIGURE 1

A. HOTTE
B. 
C. 
D. 
E.
F. TREILLIS
G.
H.
I. 
J. 
K.
L.
M. REGISTRE ROND
J
K
L
M
background
couvercle
cheminée
supérieure
couvercle
cheminée
inférieure
hotte
cabinet base
x = distance entre la hotte et la
table de cuisson
min - 24 po, suggested max - 30 po
8 3/8 po min
15 3/8 po max
23
5/8 po
4 3/4 po
36 po
FIGURE 4
AVEC
CONDUIT
x
min & max hauteurs de plafond
x = 30 po
min
8 pi
6 3/4 po
max
9 pi
1 3/4 po
x = 28 po
min
8 pi
4 3/4 po
max
8 pi
11 3/4 po
x = 26 po
min
8 pi
2 3/4 po
max
8 pi
9 3/4 po
x = 24 po
min
8 pi
3/4 po
max
8 pi

DIMENSIONS D’INSTALLATION AVEC CONDUIT
PLAN DE L’INSTALLATION

avec le Kit Pour Conversion Du Conduit. Les installations sans conduit requièrent un nécessaire approprié disponible chez
votre marchand.
AVERTISSEMENT!

La cheminée Dama Isola est réglable pour
différentes hauteurs de plafond, entre 8
pi 3/4 po and 9 pi 1 3/4 po (regardez la
distance entre la hotte et la table de cuisson
- X en FIGURE 4
utilisant plus ou moins du couvercle de
la cheminé supérieure. La FIGURE 4
illustre les dimensions de chaque pièce
du modèle Diamante Isola.
Pour des installations plus élevées de
plafond inclut une structre de soutènemant
additionnelle qui additionne 21" aux
diverses tailled de plafond sur le FIGURE
4.
  

    
PLAFOND. 
ou en panneaux muraux secs, le support
       
impossible, une structure renforcée

panneaux muraux secs. Le fabricant
   
blessures ou des dommages causés
par une installation inadéquate.
AVERTISSEMENT
!
26
11 7/16"
FIGURE 5
REMARQUE: La structure de la
cheminée peut réduire jusqu'à un
27 ".. Hauteur minimale Afin de
réduire la hauteur, la section du
milieu de la structure de soutien
(gure 5) doit être retiré Hors de
la boîte, la longueur minimale de
cheminée est de 32". Soustraire 5
"de tous les calculs au minimum la
hauteur du plafond sur la gure 4
si la suppression de la section du
milieu.
40 1/16"
background
PLAN DE L’INSTALLATION

avec le Kit Pour Conversion Du Conduit. Les installations sans conduit requièrent un nécessaire approprié disponible chez
votre marchand.
AVERTISSEMENT!

couvercle
cheminée
supérieure
couvercle
cheminée
inférieure
hotte
cabinet base
x = distance entre la hotte et la
table de cuisson
min - 24 po, suggested max - 30 po
8 3/8 po min
15
3/8 po max
23
5/8 po
36 po
FIGURE 6
SANS
CONDUIT
x
min & max hauteurs de plafond
x = 30 po
min
8 pi
6 3/4 po
max
9 pi
1 3/4 po
x = 28 po
min
8 pi
4 3/4 po
max
8 pi
11 3/4 po
x = 26 po
min
8 pi
2 3/4 po
max
8 pi
9 3/4 po
x = 24 po
min
8 pi
3/4 po
max
8 pi

DIMENSIONS D’INSTALLATION SANS CONDUIT
12 1/2 po
4 3/4 po
3 1/2
po
 
    
    
Pour

panneaux muraux secs, le support

impossible, une structure renforcée
     
ou les panneaux muraux secs.

responsable des blessures ou
des dommages causés par une
installation inadéquate.
AVERTISSEMENT
La cheminée Dama Isola sans conduit
est réglable pour différentes hauteurs
de plafond, entre 8 pi 3/4 po and 9 pi
1 3/4 po (regardez la distance entre
la hotte et la table de cuisson - X
en FIGURE 6
utilisant plus ou moins du couvercle
de la cheminé supérieure. La FIGURE
5 illustre les dimensions de chaque
pièce du modèle Diamante Isola .
Pour des installations plus élevées
de plafond inclut une structre de
soutènemant additionnelle qui
additionne 21" aux diverses tailled
de plafond sur le FIGURE 6.
!
11 7/16"
40 1/16
background
INSTALLATION DU SUPPORT
6.

pour sceller tout autour du trou. NE PAS mettre en circuit tant que
l’installation n’est pas complétée
en haut de le
TREILLIS

7. Pour installations avec conduit, placer le REGISTRE ROND (N de
la FIGURE 1) dans l'ouverture d'échappement de la hotte et appuyer
fortement sur le registre.
FIGURE 7
1. Placer un recouvrement épais
sur la plaque de cuisson, la
cuisinière encastrée ou le dessus
du comptoir pour protéger des
dommages et de la poussière.
2. Déterminer et marquer
la ligne centrale sur le mur la
hotte sera installée.
3.L de la FIGURE 7)
pour installer le support est fourni
pour marquer les trous du support
au plafond.
4. Déterminer et faire toutes les coupes nécessaires pour les conduits.
L de la FIGURE 7).
le centre exactement de le treillis.
5. Si en utilisant Le Haut Kit de Cheminée de plafond, enlever


(A de la FIGURE 8). Placez la

TREILLIS
(B de la FIGURE 8) de sorte
que les bords extérieurs et les trous électriques alignent. Attachez la PROLONGATION

TREILLIS
à l'aide des boulons (C de la FIGURE 8). Serrez les
boulons solidement.
FIGURE 10
FIGURE 8
FIGURE 9
B
C
8. Installer dans des trous forés précédemment pilotes dans le plafond
des 4 boulons, rondelles et écrous ou des vis à bois dans le sac des

du support de la cheminée.



       

12. Positionnez le support de la cheminée pour que le gros bout de
9). Puis poussez le support de la cheminée pour que les boulons sont

IMPORTANT: Le support de la cheminée doit être
solidement xé au plafond.

déterminé, installez et serrez les quatre vis.
A. Vis




background
14. RETRAIT DU COMPOSANT DE TRESTE MOYEN
REMARQUE: La structure de la cheminée peut réduire jusqu'à une hauteur minimale de 27 " . Pour
réduire la hauteur, la section médiane de la structure de support doit être retiré.
Hors de la boîte, la longueur minimale de la cheminée est de 32 ".
Aucun problème du point de vue mécanique, la rigidité est garantie par le chevauchement des colonnes.
background
Installations sans conduit
requièrent le Kit Pour
Conversion Du Conduit
(FIGURE 12). N'utilisez pas
le REGISTRE ROND (M
de la FIGURE 1) pour les
Installations sans conduit. 

(B de la FIGURE
1) et replacer avec le couvercle
de cheminée inférieure avec
  
dans le Kit Pour Conversion
Du Conduit (D de la FIGURE
12).
Illustré à la FIGURE 12, mettre
(A)
dans l'ouverture d'échappement
(E). Mettre
  
 
(B) dans le DIVERTER (A).
FIGURE 12
FIGURE 13
BRANCHER LE CÂBLE D'ALIMENTATION
       (FIGURE
11) NE PAS mettre en circuit tant que l’installation n’est
pas complétée.




INSTALLATIONS SANS CONDUIT
1.  
 
(C de la FIGURE 13)
avec les deux vis fournies
(G de la FIGURE 13).
Si
en utilisant Le Haut Kit
de Cheminée de plafond,
utilisez
 
 
avec le kit. Fixer le
 

2. 
REGISTRE ROND (M de la
FIGURE 1) et sceller toutes
les connexions avec du ruban
à conduit.
3.  
 
(B de la FIGURE 13)
avec les deux vis fournies (G
de la FIGURE 13). Fixer le
 

      
(B de la FIGURE
12)    
 (D de la FIGURE 12) et installer
les VENT GRIDS (C de la FIGURE 12).
INSTALLATION DU HOTTE

 
 
 
       
connecté à vis de terre verte

 
FIGURE 11
background
       
(F de la FIGURE 12). Voyez FIGURE 16
AVERTISSEMENT

DE LA HOTTE. 
Le fabricant n'est aucunement responsable des blessures ou des dommages causés par une installation inadéquate.
4. 
(F de la FIGURE 14) la HOTTE (A de la FIGURE 14) au treillis
prévu.
FIGURE 14
FIGURE 16
6. (de la FIGURE 17).
7.
et la lumière. Les interrupteurs de contrôle de la hotte se
trouvent à droite sous la hotte. Si la hotte ne fonctionne pas,



correctement.
5. (A de
la FIGURE 15)(B de la
FIGURE 15)
(A de la FIGURE 15)     
en plastique noire (C de la FIGURE 15) en reliant les deux
morceaux en plastique noirs à l'aide des quatre vis fournies.

(D de
la FIGURE 15).
CONNECTER LES CONNECTEURS INTERNE
FIGURE 17
!
C
A
B
D
A
B
FIGURE 15
background
FIGURE 19
Pour de meilleurs résultats
Mettre la hotte en circuit avant de commencer la cuisson. Laisser

éliminer la fumée et les odeurs de la cuisine.
Nettoyage

dans 
      
sur les hottes en acier inoxydable. Ne pas utiliser de produits

     

Remplacement de la lumière halogène
       
        (de la
FIGURE 19). 
ampoule.

des 1 1/4"tasses d'aspiration (de la FIGURE 20). Attachez la
tasse d'aspiration à l'ampoule et tirez fermement vers le bas sur
l'ampoule et la substituez avec une nouvelle lampe.

DIAGRAMME DE CÂBLAGE
FIGURE 20
FIGURE 18
UTILISATION ET ENTRETIEN

cuisson et les odeurs de la cuisine.
Panneau de commandes
Le panneau de commandes est situé sur le devant de la hotte.
La position et la fonction de chaque bouton sont indiquées à
la FIGURE 18.
0 1 2 3 4 5 6 7 8 9
Creato da.
Rev :
Ver :
DOLCE CORRADO
Materiali: non deveno contenere Pb, Cr6+, Hg, PBB, pbde, ai sensi della direttiva 2002/95 CE
SCHEMA ELETTRICO M8-4V ESB FARETTI
Non rilevare quote dal grafico non ap portare modifiche senza l'autorizzazione d'ufficio progettazione
a termini di legge ci riserviamo la prop rieta' del presente disegno con divieto di riproduzione totale o parziale
Code :
Disegno N :
Data:
08.Set.2010
LINE IN
120Vac
60Hz ~
L
N
Y-G
WIRING BOX
BLU
RED
BLK
WHT
Y-G
1
2
3
4
5
6
BLK
V1
MC
F
V2
ESB
0
MOTOR
1
MOTOR
BRW
GRY
BLU
123
6 5 4
789
1 2 3
654
987
RED
M8 4V
120V ~
WHT
BRW
2
SPEED
BLU
BLK
1
1
BLK
BLK
WHT
2
2
WHT
ORG
BRW
3
3
BRW
GRY
4
4
GRY
RED
WHT
BLU
Y-G
BLU
5
5
BLU
3/I
SPEED
RED
6
6
RED
WHT
7
7
WHT
VLT(ORG)
8
8
VLT(ORG)
RED(ORG)
9
9
RED(ORG)
RED
10
10
RED
VLT
11
11
VLT
0-1
LIGHT
12
12
TOROIDAL
TRANSFORMER
WHT
4
3
BLK
RED
2
1
BLK
N
L
V4
L
V3
ORG
2
1
RED
ORG
4
3
VLT
WHT
1
2
3
4
5
6
ORG
WHT
BRW
GRY
ORG
RED(ORG)
VLT(ORG)
RED
VLT
PRI.
SEC.
ELECTRONIC
TRNSFORMER
VLT
RED
HALOGEN
LAMPS
VLT
INCANDESCENT
LAMP
RED
HALOGEN
LAMPS
HALOGEN
LAMPS
HALOGEN
LAMPS
L
V
M
Bouton marche-arrêt de la lumière (L)


Ventilateur outre de bouton (M)

actionné en appuyant sur les boutons l'uns des de vitesse
Bouton de vitesse du ventilateur (V)
         
commutateur ; 1" ; pour à vitesse réduite, " ; 2" ; pour la vitesse

la vitesse 3 pendant 5 secondes pour activer la vitesse intensive.

renvoie alors la vitesse précédente.
background
FABER GARANTIE ET SERVICE (
ÉCONOMISER POUR VOS ENREGISTREMENTS
)





Les frais suivants ne sont pas couverts par la garantie Faber :
 
comment utiliser votre hotte de cuisinière, pour remplacer ou réparer les fusibles de votre maison ou

2. Les appels de service pour remplacer ou réparer les ampoules, les fusibles ou les

3. Les réparations lorsque votre hotte de cuisinière a été utilisée plus que la normale,
c'est-à-dire plus que pour une famille par foyer.
 


 


 
 
Enregistrez Votre Information Ci-dessous:
Séquentiel #: __________________________
Date d'achat: ______________
background
background

Specifications

Indexed Terms: Halogen Oven, Convection

Faber DAMIS36SS Questions and Answers

Questions and Answers

Related Products

No image
Faber 6032409 Nova Halogen
2020-12-25 2 docs
No image
Faber 6044788 Isola Halogen
2020-12-24 2 docs
No image
Faber 6044787 Isola Halogen
2020-12-24 2 docs
No image
Faber 6044789 Isola Halogen
2020-12-24 2 docs