2. Ducts must be of adequate size and duct runs should be as short as possible. Where turns are necessary,
keep turning radius as large and as smooth as possible.
3. The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct joint. Then, seal the duct
joints with high quality duct tape.
4. Do not use this unit with any solid-state speed control device.
5. This unit must be grounded.
INSTALLATION INSTRUCTIONS
WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction codes and standards.
b) Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guidelines and safety
standards such as those published by the National Fire Protection Association (NFPA) and the American Society
for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d) Ducted fans must always be vented to the outdoors.
e) For safe and secure wall mounting, the HEAT
®
BBQ Hood should be mounted to a solid vertical surface of
sufficient width to allow for mounting of the Hood. The horizontal surface should extend from a vertical plane to the
point directly in front of the exhaust roof cap (or wall cap).
f) The Hood should be installed with a MINIMUM of three (3) feet of weather proof roof coverage on all sides that
are not protected from direct rain by an adjacent wall.
g) It is also required that all duct work and roof openings be thoroughly sealed with the applicable tape and/or roof
sealant to prevent ingress of water.
WARNING -- TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION To reduce the risk of fire and to properly exhaust air, be sure to duct air outside Do not
vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
PART 1 Planning the Installation
CAUTION:
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To reduce the risk of fire and to properly exhaust air, the hood must be exhausted to outside air. Never
exhaust into a wall, an attic or a concealed area in the building. This can create a potential hazard.
3. Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting.
4. Locate the cooking area for minimum cross draftsaway from doors and windows, when possible.