ElectriQ P16HP 16000 BTU 4.6 Kw Portable Air Conditioner with Heat Pump up to 42 sqm

User Manual - Page 4

For P16HP.

PDF File Manual, 15 pages, Read Online | Download pdf file

P16HP photo
Loading ...
Loading ...
Loading ...
Page 4 of 15
R290 refrigerant gas complies with European environmental directives. R290 has
a low GWP (Global Warming Potential) of 3.
The P16HP contains about 225 g of R290 refrigerant gas, and the P18HP contains
about 300g of R290 refrigerant gas.
Do not use or store in unventilated spaces with an area smaller than 10.8 m
2
per
unit for P16HP and 14.4 m
2
per unit for P18HP. The room must be such as to
prevent stagnation of possible leaks of refrigerant gas as there could be a danger
of fire or explosion hazard should the refrigerant come into contact with electric
heaters, stoves or other sources of ignition.
Do not use the product and contact the retailer for advice, if damage has occurred
to the unit which may have compromised the refrigerant system.
Do not open the air conditioner, to attempt service or repair the unit. Any internal
servicing of the unit must be carried out only by the manufacturer or its authorized
technicians.
Any repairs or maintenance must only be carried out on the unit by a suitably
qualified engineer. Before opening and servicing the unit the authorized engineer
must be in possession of a copy of the manufacturer’s service manual and must
follow the safety information contained within it to ensure all hazards are minimized.
The refrigerant system should not be perforated or punctured.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (For example: open flames, an operating gas appliance or an operating
electric heater)
ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS
Do not cover or restrict the airflow from the outlet or inlet grills.
For maximum performance the air conditioner should be situated at least 50cm from the
walls or other objects.
Keep the filters clean. Under normal conditions, filters should only need cleaning once
every three weeks (approximately). Since the filters remove airborne particles, more
frequent cleaning maybe necessary, depending on the air quality.
For the initial start-up set the fan speed to maximum and the thermostat to 4-5 degrees
lower than the current temperature. After, set the fan to low and set the thermostat to your
desired setting.
To protect the unit we recommend the unit should only be used when the temperature of
the room is between 7°C and 35°C. If the temperature is below this use electrical
heating to raise the temperature above 10⁰C before starting the unit.