ElectriQ P16HP 16000 BTU 4.6 Kw Portable Air Conditioner with Heat Pump up to 42 sqm

User Manual - Page 11

For P16HP.

PDF File Manual, 15 pages, Read Online | Download pdf file

P16HP photo
Loading ...
Loading ...
Loading ...
Page 11 of 15
REMOTE CONTROL
The functions on the remote are the same as those on the main control
panel
WATER-DRAINAGE
MANUAL DRAINAGE:
1. When the internal water tank is full the unit will stop working and the TANK FULL indicator
will illuminate.
2. Shut off the unit and unplug. Try not to move the model abruptly as this may cause water
to spill out from internal water tank.
3. Place a tray under the water plug.
4. Unscrew the water plug (A) and remove the rubber bung (B) - water will drain from the
internal tank.
5. When drained replace the rubber bung and screw the water plug back into place
CONTINUOUS DRAINAGE:
Continuous drainage should be set up when the unit is used
in heating or dehumidify modes.
1. Unscrew the water plug (A) and remove the rubber
bung (B).
2. Connect a suitably sized water pipe to the port.
3. You can plumb this pipe into your current plumbing
system, lead it outside or use a water pump.
Note: This model has a self-evaporative function, which reduces the need to empty the water
tank while in cooling mode. If the unit is vented correctly most of the water is reused to
cool the condenser coils and any excess is evaporated. Please do not use continuous
drainage if you intend to use the self-evaporating facility. In heating or dehumidifier mode
we advise to use the continuous drainage.
1. POWER – ON/OFF Switch
2. MODE – Operation Mode
3. TIMER – Timer Mode
4. SPEED – Fan Speed Selector
5. TEMP+ - Temperature Up
6. TEMP- – Temperature Down
7. SLEEP
8. SWING
Loading ...
Loading ...
Loading ...